Please use this identifier to cite or link to this item: https://doi.org/10.3389/fbioe.2023.1191162
Title: Engineering Escherichia coli for diagnosis and management of hyperuricemia
Authors: Gencer, Gozde
Mancuso, Christopher
Chua, Koon Jiew 
Ling, Hua 
Costello, Cait M
Chang, Matthew Wook 
March, John C
Issue Date: 23-May-2023
Publisher: Frontiers Media SA
Citation: Gencer, Gozde, Mancuso, Christopher, Chua, Koon Jiew, Ling, Hua, Costello, Cait M, Chang, Matthew Wook, March, John C (2023-05-23). Engineering Escherichia coli for diagnosis and management of hyperuricemia. Frontiers in Bioengineering and Biotechnology 11. ScholarBank@NUS Repository. https://doi.org/10.3389/fbioe.2023.1191162
Abstract: Uric acid disequilibrium is implicated in chronic hyperuricemia-related diseases. Long-term monitoring and lowering of serum uric acid levels may be crucial for diagnosis and effective management of these conditions. However, current strategies are not sufficient for accurate diagnosis and successful long-term management of hyperuricemia. Moreover, drug-based therapeutics can cause side effects in patients. The intestinal tract plays an important role in maintaining healthy serum acid levels. Hence, we investigated the engineered human commensal Escherichia coli as a novel method for diagnosis and long-term management of hyperuricemia. To monitor changes in uric acid concentration in the intestinal lumen, we developed a bioreporter using the uric acid responsive synthetic promoter, pucpro, and uric acid binding Bacillus subtilis PucR protein. Results demonstrated that the bioreporter module in commensal E. coli can detect changes in uric acid concentration in a dose-dependent manner. To eliminate the excess uric acid, we designed a uric acid degradation module, which overexpresses an E. coli uric acid transporter and a B. subtilis urate oxidase. Strains engineered with this module degraded all the uric acid (250 µM) found in the environment within 24 h, which is significantly lower (p < 0.001) compared to wild type E. coli. Finally, we designed an in vitro model using human intestinal cell line, Caco-2, which provided a versatile tool to study the uric acid transport and degradation in an environment mimicking the human intestinal tract. Results showed that engineered commensal E. coli reduced (p < 0.01) the apical uric acid concentration by 40.35% compared to wild type E. coli. This study shows that reprogramming E. coli holds promise as a valid alternative synthetic biology therapy to monitor and maintain healthy serum uric acid levels.
Source Title: Frontiers in Bioengineering and Biotechnology
URI: https://scholarbank.nus.edu.sg/handle/10635/242057
ISSN: 2296-4185
DOI: 10.3389/fbioe.2023.1191162
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Engineering Escherichia coli for diagnosis and management of hyperuricemia.pdfPublished version2.26 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.