Please use this identifier to cite or link to this item: https://doi.org/https://doi.org/10.1109/TEC.2023.3260191
Title: Adaptive Grid-Supportive Control for Solar-Power Integrated Electric-Vehicle Fast Charging Station
Authors: Jaydeep Saha 
Nishant Kumar 
Sanjib K Panda 
Keywords: Fast-charging-station (FCS)
Plug-in electric vehicles (PEVs)
Power Conversion
Solar photo-voltaic (PV)
Power ramp-rate control (PRRC)
Issue Date: 22-Mar-2023
Publisher: IEEE Transactions on Energy Conversion
Citation: Jaydeep Saha, Nishant Kumar, Sanjib K Panda (2023-03-22). Adaptive Grid-Supportive Control for Solar-Power Integrated Electric-Vehicle Fast Charging Station. ScholarBank@NUS Repository. https://doi.org/https://doi.org/10.1109/TEC.2023.3260191
Rights: CC0 1.0 Universal
Abstract: Though the Medium-voltage (MV) grid-connected solid-state-transformer ( SST ) based plug-in electric-vehicle fast-charging station (PEV-FCS) solutions provide a reduction in grid side current-stress, integration of solar-power in such SST -based PEV-FCS (which can potentially reduce grid side current-stress further) and its implementation with grid-compliant control is not explored in literature. In this paper, an adaptive automatic generation control supportive maximum power point tracking (AGCS-MPPT) technique for solar-power integration is proposed and experimentally validated for a bidirectional SST -based PEV-FCS while following the EN 50530 standard's testing sequence. Respective European and Californian MPPT efficiencies ( ξEuro , ξCEC ) of 99.50%, 99.55% and 99.49%, 99.55% are observed for solar-power integration through AGCS-MPPT technique during G2V and V2G functional modes of the PEV-FCS, which are better compared to those of state-of-the-art technique (SoAT) and improved perturb and observe (P&O) MPPT algorithms. Unlike the SoAT and P&O, the AGCS-MPPT algorithm assists the PEV-FCS in adhering to the utility grid's power ramp-rate constraint while integrating intermittent solar-power, both during ξEuro -test and ξCEC -test sequences. The AGCS-MPPT also displays excellent MPPT efficiency ( ∼ 99.2%) and solar-power integration performance during the dynamic-test sequence as per EN 50530 standard. Grid side current's THD < 2.2% and near unity power-factor (UPF) at grid side are observed during the experimentation of PEV-FCS under various solar-power penetrations.
URI: https://scholarbank.nus.edu.sg/handle/10635/238418
ISSN: 0885-8969
1558-0059
DOI: https://doi.org/10.1109/TEC.2023.3260191
Rights: CC0 1.0 Universal
Appears in Collections:Elements
Staff Publications

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
2. IEEE_TEC_FCS_Final version.pdfIEEE_TEC_preprint9.98 MBAdobe PDF

OPEN

Post-printView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons