Please use this identifier to cite or link to this item: https://doi.org/10.1186/s13104-022-06033-z
Title: Validation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline
Authors: Grafton-Clarke, C
Njoku, P
Aben, JP
Ledoux, L
Zhong, L 
Westenberg, J
Swift, A
Archer, G
Wild, J
Hose, R
Flather, M
Vassiliou, VS
Garg, P
Keywords: Aortic stenosis
Cardiac MRI
Validation
Aortic Valve
Aortic Valve Stenosis
Blood Flow Velocity
Echocardiography
Echocardiography, Doppler
Humans
Issue Date: 1-Dec-2022
Publisher: Springer Science and Business Media LLC
Citation: Grafton-Clarke, C, Njoku, P, Aben, JP, Ledoux, L, Zhong, L, Westenberg, J, Swift, A, Archer, G, Wild, J, Hose, R, Flather, M, Vassiliou, VS, Garg, P (2022-12-01). Validation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline. BMC Research Notes 15 (1) : 151-. ScholarBank@NUS Repository. https://doi.org/10.1186/s13104-022-06033-z
Abstract: Objective: Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. Results: We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 ± 35.2 mmHg using the invasive pressure drop method and 52.2 ± 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography.
Source Title: BMC Research Notes
URI: https://scholarbank.nus.edu.sg/handle/10635/226754
ISSN: 17560500
DOI: 10.1186/s13104-022-06033-z
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Validation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline.pdfPublished version1.17 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.