Please use this identifier to cite or link to this item: https://doi.org/10.1007/s00421-011-1834-2
Title: Accuracy of a novel multi-sensor board for measuring physical activity and energy expenditure
Authors: Duncan, Glen E
Lester, Jonathan
Migotsky, Sean
Goh, Jorming 
Higgins, Lisa
Borriello, Gaetano
Keywords: Science & Technology
Life Sciences & Biomedicine
Physiology
Sport Sciences
Accuracy
Methodology
Technology
Validation
ACTIVITY MODE
PREVENTION
DISEASE
INTERVENTION
SYSTEM
Issue Date: 1-Sep-2011
Publisher: SPRINGER
Citation: Duncan, Glen E, Lester, Jonathan, Migotsky, Sean, Goh, Jorming, Higgins, Lisa, Borriello, Gaetano (2011-09-01). Accuracy of a novel multi-sensor board for measuring physical activity and energy expenditure. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY 111 (9) : 2025-2032. ScholarBank@NUS Repository. https://doi.org/10.1007/s00421-011-1834-2
Abstract: The ability to relate physical activity to health depends on accurate measurement. Yet, none of the available methods are fully satisfactory due to several factors. This study examined the accuracy of a multi-sensor board (MSB) that infers activity types (sitting, standing, walking, stair climbing, and running) and estimates energy expenditure in 57 adults (32 females) 39.2 ± 13.5 years. In the laboratory, subjects walked and ran on a treadmill over a select range of speeds and grades for 3 min each (six stages in random order) while connected to a stationary calorimeter, preceded and followed by brief sitting and standing. On a different day, subjects completed scripted activities in the field connected to a portable calorimeter. The MSB was attached to a strap at the right hip. Subjects repeated one condition (randomly selected) on the third day. Accuracy of inferred activities compared with recorded activities (correctly identified activities/total activities × 100) was 97 and 84% in the laboratory and field, respectively. Absolute accuracy of energy expenditure [100 - absolute value (kilocalories MSB - kilocalories calorimeter/kilocalories calorimeter) × 100] was 89 and 76% in the laboratory and field, the later being different (P<0.05) from the calorimeter. Test-retest reliability for energy expenditure was significant in both settings (P<0.0001; r = 0.97). In general, the MSB provides accurate measures of activity type in laboratory and field settings and energy expenditure during treadmill walking and running although the device underestimates energy expenditure in the field. © Springer-Verlag 2011.
Source Title: EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
URI: https://scholarbank.nus.edu.sg/handle/10635/219460
ISSN: 1439-6319
1439-6327
DOI: 10.1007/s00421-011-1834-2
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Duncan 2011 - Accuracy of a novel multi-sensor board for measuring physical activity and energy expenditure.pdf294.28 kBAdobe PDF

CLOSED

None

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.