Please use this identifier to cite or link to this item: https://doi.org/10.1038/s41598-019-51062-7
Title: A Deep Learning Approach to Denoise Optical Coherence Tomography Images of the Optic Nerve Head
Authors: Devalla, S.K.
Subramanian, G.
Pham, T.H. 
Wang, X. 
Perera, S.
Tun, T.A. 
Aung, T.
Schmetterer, L.
Thiéry, A.H. 
Girard, M.J.A.
Issue Date: 2019
Publisher: Nature Publishing Group
Citation: Devalla, S.K., Subramanian, G., Pham, T.H., Wang, X., Perera, S., Tun, T.A., Aung, T., Schmetterer, L., Thiéry, A.H., Girard, M.J.A. (2019). A Deep Learning Approach to Denoise Optical Coherence Tomography Images of the Optic Nerve Head. Scientific Reports 9 (1) : 14454. ScholarBank@NUS Repository. https://doi.org/10.1038/s41598-019-51062-7
Rights: Attribution 4.0 International
Abstract: Optical coherence tomography (OCT) has become an established clinical routine for the in vivo imaging of the optic nerve head (ONH) tissues, that is crucial in the diagnosis and management of various ocular and neuro-ocular pathologies. However, the presence of speckle noise affects the quality of OCT images and its interpretation. Although recent frame-averaging techniques have shown to enhance OCT image quality, they require longer scanning durations, resulting in patient discomfort. Using a custom deep learning network trained with 2,328 ‘clean B-scans’ (multi-frame B-scans; signal averaged), and their corresponding ‘noisy B-scans’ (clean B-scans + Gaussian noise), we were able to successfully denoise 1,552 unseen single-frame (without signal averaging) B-scans. The denoised B-scans were qualitatively similar to their corresponding multi-frame B-scans, with enhanced visibility of the ONH tissues. The mean signal to noise ratio (SNR) increased from 4.02 ± 0.68 dB (single-frame) to 8.14 ± 1.03 dB (denoised). For all the ONH tissues, the mean contrast to noise ratio (CNR) increased from 3.50 ± 0.56 (single-frame) to 7.63 ± 1.81 (denoised). The mean structural similarity index (MSSIM) increased from 0.13 ± 0.02 (single frame) to 0.65 ± 0.03 (denoised) when compared with the corresponding multi-frame B-scans. Our deep learning algorithm can denoise a single-frame OCT B-scan of the ONH in under 20 ms, thus offering a framework to obtain superior quality OCT B-scans with reduced scanning times and minimal patient discomfort. © 2019, The Author(s).
Source Title: Scientific Reports
URI: https://scholarbank.nus.edu.sg/handle/10635/212099
ISSN: 20452322
DOI: 10.1038/s41598-019-51062-7
Rights: Attribution 4.0 International
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1038_s41598-019-51062-7.pdf2.33 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons