Please use this identifier to cite or link to this item: https://doi.org/10.1007/s11239-021-02575-4
Title: Global haemostatic tests demonstrate the absence of parameters of hypercoagulability in non-hypoxic mild COVID-19 patients: a prospective matched study
Authors: Fan, Bingwen Eugene
Ramanathan, Kollengode 
Sum, Christina Lai Lin
Christopher, Dheepa
Chan, Stephrene Seok Wei
Lim, Gek Hsiang 
Bok, Chwee Fang
Wong, Shiun Woei
Lye, David Chien 
Young, Barnaby Edward
Lim, Jia Yan
Lee, Rui Min
Lim, Shu Ping
Tan, Hwee Tat
Ang, Mui Kia
Lau, Soon Lee
Kuperan, Ponnudurai
Ong, Kiat Hoe 
Chia, Yew Woon 
Keywords: Thrombelastography
COVID-19
SARS-CoV-2
Hypercoagulability
Venous thromboembolism
Issue Date: 28-Sep-2021
Publisher: SPRINGER
Citation: Fan, Bingwen Eugene, Ramanathan, Kollengode, Sum, Christina Lai Lin, Christopher, Dheepa, Chan, Stephrene Seok Wei, Lim, Gek Hsiang, Bok, Chwee Fang, Wong, Shiun Woei, Lye, David Chien, Young, Barnaby Edward, Lim, Jia Yan, Lee, Rui Min, Lim, Shu Ping, Tan, Hwee Tat, Ang, Mui Kia, Lau, Soon Lee, Kuperan, Ponnudurai, Ong, Kiat Hoe, Chia, Yew Woon (2021-09-28). Global haemostatic tests demonstrate the absence of parameters of hypercoagulability in non-hypoxic mild COVID-19 patients: a prospective matched study. JOURNAL OF THROMBOSIS AND THROMBOLYSIS. ScholarBank@NUS Repository. https://doi.org/10.1007/s11239-021-02575-4
Abstract: Severe COVID-19 patients demonstrate hypercoagulability, necessitating thromboprophylaxis. However, less is known about the haemostatic profile in mild COVID-19 patients. We performed an age and gender-matched prospective study of 10 severe and 10 mild COVID-19 patients. Comprehensive coagulation profiling together with Thromboelastography and Clot Waveform Analysis were performed. FBC, PT, APTT, D-dimer, fibrinogen and CWA were repeated every 3 days for both groups and repeat TEG was performed for severe patients up till 15 days. On recruitment, severe patients had markers reflecting hypercoagulability including raised median D-dimer 1.0 μg/mL (IQR 0.6, 1.4) (p = 0.0004), fibrinogen 5.6 g/L (IQR 4.9, 6.6) (p = 0.002), Factor VIII 206% (IQR 171, 203) and vWF levels 265.5% (IQR 206, 321). Mild patients had normal values of PT, aPTT, fibrinogen and D-dimer, and slightly elevated median Factor VIII and von Willebrand factor (vWF) levels. Repeated 3-day assessments for both groups showed declining trends in D-dimer and Fibrinogen. CWA of severe COVID-19 group demonstrated hypercoagulability with an elevated median values of aPTT delta change 78.8% (IQR 69.8, 85.2) (p = 0.001), aPTT clot velocity (min1) 7.8%/s (IQR 6.7, 8.3) (p = 0.001), PT delta change 22.4% (IQR 19.4, 29.5) (p = 0.004), PT min1 7.1%/s (IQR 6.3, 9.0) (p = 0.02), PT clot acceleration (min 2) 3.6%/s2 (IQR 3.2, 4.5) (p = 0.02) and PT clot deceleration (max2) 2.9%/s2 (IQR 2.5, 3.5) (p = 0.02). TEG of severe patients reflected hypercoagulability with significant increases in the median values of CFF MA 34.6 mm (IQR 27.4,38.6) (p = 0.003), CRT Angle 78.9° (IQR 78.3, 80.0) (p = 0.0006), CRT A10 67.6 mm (IQR 65.8, 69.6) (p = 0.007) and CFF A10 32.0 mm (IQR 26.8, 34.0) (p = 0.003). Mild COVID-19 patients had absent hypercoagulability in both CWA and TEG. 2 severe patients developed thromboembolic events while none occurred in the mild COVID-19 group. Mild COVID-19 patients show absent parameters of hypercoagulability in global haemostatic tests while those with severe COVID-19 demonstrated parameters associated with hypercoagulability on the global haemostatic tests together with raised D-Dimer, fibrinogen, Factor VIII and vWF levels.
Source Title: JOURNAL OF THROMBOSIS AND THROMBOLYSIS
URI: https://scholarbank.nus.edu.sg/handle/10635/206081
ISSN: 09295305
1573742X
DOI: 10.1007/s11239-021-02575-4
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Global haemostatic tests demonstrate the absence of parameters of hypercoagulability in non-hypoxic mild COVID-19 patients a.pdf804.04 kBAdobe PDF

CLOSED

Published

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.