Please use this identifier to cite or link to this item: https://doi.org/10.1259/bjr.20210835
Title: The effectiveness of the Safety in Interventional Radiology (SIR) Shield in reducing droplet transmission and its effect on image quality and radiation dose.
Authors: Ong, Shao Jin
Anil, Gopinathan 
Chia, Koon Liang
Khoo, Deborah
Lee, Joseph Kt
Chen, Priscilla Xh
Nares, Teddy M
Koh, Calvin J
Su, Peijing 
Yang, Cunli
Singh, Pavel
Rajendran, Prapul C
Fotheringham, Timothy
Quek, Swee T 
Renfrew, Ian
Issue Date: 21-Oct-2021
Publisher: British Institute of Radiology
Citation: Ong, Shao Jin, Anil, Gopinathan, Chia, Koon Liang, Khoo, Deborah, Lee, Joseph Kt, Chen, Priscilla Xh, Nares, Teddy M, Koh, Calvin J, Su, Peijing, Yang, Cunli, Singh, Pavel, Rajendran, Prapul C, Fotheringham, Timothy, Quek, Swee T, Renfrew, Ian (2021-10-21). The effectiveness of the Safety in Interventional Radiology (SIR) Shield in reducing droplet transmission and its effect on image quality and radiation dose.. Br J Radiol : 20210835-. ScholarBank@NUS Repository. https://doi.org/10.1259/bjr.20210835
Abstract: OBJECTIVE: To evaluate the efficacy of a barrier shield in reducing droplet transmission and its effect on image quality and radiation dose in an interventional suite. METHODS: A human cough droplet visualisation model in a supine position was developed to assess efficacy of barrier shield in reducing environmental contamination. Its effect on image quality (resolution and contrast) was evaluated via image quality test phantom. Changes in the radiation dose to patient post-shield utilisation was measured. RESULTS: Use of the shield prevented escape of visible fluorescent cough droplets from the containment area. No subjective change in line-pair resolution was observed. No significant difference in contrast-to-noise ratio was measured. Radiation dosage to patient was increased; this is predominantly attributed to the increased air gap and not the physical properties of the shield. CONCLUSION: Use of the barrier shield provided an effective added layer of personal protection in the interventional radiology theatre for aerosol generating procedures. ADVANCES IN KNOWLEDGE: This is the first time a human supine cough droplet visualisation has been developed. While multiple types of barrier shields have been described, this is the first systematic practical evaluation of a barrier shield designed for use in the interventional radiology theatre.
Source Title: Br J Radiol
URI: https://scholarbank.nus.edu.sg/handle/10635/205964
ISSN: 00071285
1748880X
DOI: 10.1259/bjr.20210835
Appears in Collections:Elements
Staff Publications

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
44) BJR SIR Helmet 2021.pdfPublished version170.6 kBAdobe PDF

CLOSED

None

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.