Please use this identifier to cite or link to this item: https://doi.org/10.5194/gmd-13-335-2020
Title: An urban ecohydrological model to quantify the effect of vegetation on urban climate and hydrology (UT&C v1.0)
Authors: Meili, N.
Manoli, G.
Burlando, P.
Bou-Zeid, E.
Chow, W.T.L.
Coutts, A.M.
Daly, E.
Nice, K.A.
Roth, M. 
Tapper, N.J.
Velasco, E.
Vivoni, E.R.
Fatichi, S.
Issue Date: 2020
Publisher: Copernicus GmbH
Citation: Meili, N., Manoli, G., Burlando, P., Bou-Zeid, E., Chow, W.T.L., Coutts, A.M., Daly, E., Nice, K.A., Roth, M., Tapper, N.J., Velasco, E., Vivoni, E.R., Fatichi, S. (2020). An urban ecohydrological model to quantify the effect of vegetation on urban climate and hydrology (UT&C v1.0). Geoscientific Model Development 13 (1) : 335-362. ScholarBank@NUS Repository. https://doi.org/10.5194/gmd-13-335-2020
Rights: Attribution 4.0 International
Abstract: Increasing urbanization is likely to intensify the urban heat island effect, decrease outdoor thermal comfort, and enhance runoff generation in cities. Urban green spaces are often proposed as a mitigation strategy to counteract these adverse effects, and many recent developments of urban climate models focus on the inclusion of green and blue infrastructure to inform urban planning. However, many models still lack the ability to account for different plant types and oversimplify the interactions between the built environment, vegetation, and hydrology. In this study, we present an urban ecohydrological model, Urban Tethys-Chloris (UT&C), that combines principles of ecosystem modelling with an urban canopy scheme accounting for the biophysical and ecophysiological characteristics of roof vegetation, ground vegetation, and urban trees. UT&C is a fully coupled energy and water balance model that calculates 2m air temperature, 2m humidity, and surface temperatures based on the infinite urban canyon approach. It further calculates the urban hydrological fluxes in the absence of snow, including transpiration as a function of plant photosynthesis. Hence, UT&C accounts for the effects of different plant types on the urban climate and hydrology, as well as the effects of the urban environment on plant well-being and performance. UT&C performs well when compared against energy flux measurements of eddy-covariance towers located in three cities in different climates (Singapore, Melbourne, and Phoenix). A sensitivity analysis, performed as a proof of concept for the city of Singapore, shows a mean decrease in 2m air temperature of 1.1 °C for fully grass-covered ground, 0.2 °C for high values of leaf area index (LAI), and 0.3 °C for high values of Vc,max (an expression of photosynthetic capacity). These reductions in temperature were combined with a simultaneous increase in relative humidity by 6.5 %, 2.1 %, and 1.6 %, for fully grass-covered ground, high values of LAI, and high values of Vc,max, respectively. Furthermore, the increase of pervious vegetated ground is able to significantly reduce surface runoff. © Author(s) 2020.
Source Title: Geoscientific Model Development
URI: https://scholarbank.nus.edu.sg/handle/10635/199031
ISSN: 1991-959X
DOI: 10.5194/gmd-13-335-2020
Rights: Attribution 4.0 International
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_5194_gmd_13_335_2020.pdf2.28 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons