Please use this identifier to cite or link to this item: https://doi.org/10.1115/1.4044623
Title: An Investigation on Ventilation of Building-Integrated Photovoltaics System Using Numerical Modeling
Authors: Lau, Siu-Kit 
Zhao, Yong 
Lau, Stephen Siu Yu 
Yuan, Chao 
Shabunko, Veronika 
Keywords: BIPV
CFD
ventilation
cooling
PV performance
temperature
design
environmental conditions
building
exergy
heat transfer
photovoltaics
renewable
simulation
sustainability
Issue Date: 1-Feb-2020
Publisher: ASME
Citation: Lau, Siu-Kit, Zhao, Yong, Lau, Stephen Siu Yu, Yuan, Chao, Shabunko, Veronika (2020-02-01). An Investigation on Ventilation of Building-Integrated Photovoltaics System Using Numerical Modeling. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME 142 (1). ScholarBank@NUS Repository. https://doi.org/10.1115/1.4044623
Abstract: This study numerically investigates the thermal behavior and airflow characteristics of the building-integrated photovoltaic (BIPV) façade. A three-dimensional model is developed based on the typical BIPV façade. Computational fluid dynamics (CFD) with the shear stress transport (SST) κ-omega turbulent model is used in the study. The effects of geometric configurations on the BIPV cell temperature in steady state are evaluated including the sizes of the bottom and top openings and the depth of the back air cavity (or so-called cavity depth). When the sizes of the inlet and outlet openings are the same, the effects on the decrease of cell temperature are limited. By enlarging the bottom (inlet) opening, the impact of ventilation in the cavity behind is more significant and the cell temperature decreases. Cavity depth is also a vital factor affecting BIPV cell temperature. The paper identifies the optimal cavity depth of approximately 100–125 mm. Flow disturbance and a vortex may be observed at the bottom and top of the air cavity, respectively, as the cavity depth increases which negatively affects the ventilation causing these flow disturbances to increase the cell temperature. Thermal effects of environmental conditions are compared with regard to two selected BIPV configurations. The wind velocity and the attack angle also have an obvious impact on cell temperature. Ambient temperature and solar irradiance exhibit a linear relationship with BIPV cell temperature as expected.
Source Title: JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME
URI: https://scholarbank.nus.edu.sg/handle/10635/172229
ISSN: 01996231
15288986
DOI: 10.1115/1.4044623
Appears in Collections:Elements
Staff Publications

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
2019 An Investigation on Ventilation of building-Integrated Photovoltaics system Using Numerical Modeling.pdf931.72 kBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.