Please use this identifier to cite or link to this item:
https://doi.org/10.1109/IPGC.2008.4781383
Title: | Automated algorithm for standardized quantification on liver fibrosis using second harmonic generation microscopy | Authors: | Tai, D.C.S. Tan, N. Chia, S.M. Xu, S.Y. Kang, C.H. Yu, H. |
Keywords: | Automated algorithm Collagen Liver fibrosis Quantification Second harmonic generation |
Issue Date: | 2008 | Citation: | Tai, D.C.S.,Tan, N.,Chia, S.M.,Xu, S.Y.,Kang, C.H.,Yu, H. (2008). Automated algorithm for standardized quantification on liver fibrosis using second harmonic generation microscopy. 2008 IEEE PhotonicsGlobal at Singapore, IPGC 2008 : -. ScholarBank@NUS Repository. https://doi.org/10.1109/IPGC.2008.4781383 | Abstract: | BACKGROUND Determining the extent of liver fibrosis has clinically been difficult due to the lack of a simple, objective method that can accurately quantify the amount of collagen in the diseased tissue. Second harmonic generation (SHG) mi-croscopy has been shown to produce bright and robust signals from non-centrosymmetric fibrillar collagen. We designed a SHG system that can objectively measure collagen presence in livers. In addition, we have developed a fully automated algorithm to quantify liver fibrosis in an efficient, standardized and reproducible manner. METHODS SHG microscopy was performed on livers harvested from bile duct ligated Wistar rats using a confocal micro- scope with a mode-locked Ti:Sapphire laser. Images acquired were later analyzed with Otsu method and a custom-developed, fully automated algorithm to measure area of fibers. RESULTS Both the qualitative and quantitative progression of collagen over time was observed using SHG microscopy. We have compared the modified quantification algorithm with Otsu segmentation algorithm. With the modified algorithm, we have maintained greater amount of collage after segmentation. We have also shown modified algorithm was able to identify the presence of finer collagen which was completely removed with the normal Otsu method. CONCLUSION We have built an imaging system using state-of-the-art SHG microscopy. In addition, a fully-automated algorithm was developed to quantify collagen content in tissue to measure the presence of collagen in high accuracy. By combining SHG microscopy and our quantification algorithm, we can provide sensitive measurement for liver fibrosis which accurately reflects the progression of liver fibrosis, especially in early stages. | Source Title: | 2008 IEEE PhotonicsGlobal at Singapore, IPGC 2008 | URI: | http://scholarbank.nus.edu.sg/handle/10635/115385 | ISBN: | 9781424429059 | DOI: | 10.1109/IPGC.2008.4781383 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.