Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/91675
Title: Relay-based on-line monitoring procedures for 2 × 2 and 3 × 3 multiloop control systems
Authors: Ju, J. 
Issue Date: 1997
Citation: Ju, J. (1997). Relay-based on-line monitoring procedures for 2 × 2 and 3 × 3 multiloop control systems. Industrial and Engineering Chemistry Research 36 (6) : 2225-2230. ScholarBank@NUS Repository.
Abstract: A monitoring procedure is proposed to identify on-line the maximum closed-loop log modulus, Lc,max, for multiloop control systems. Lc,max is considered because it measures the robustness of the control systems and thereby can indicate the appropriateness of controller design with respect to the current operating conditions. The proposed method identifies Lc,max via relay feedback experiments without requiring a priori information of process conditions. This procedure is applied to both linear systems and nonlinear systems. The results show that the proposed method is efficient and accurate in on-line identification of Lc,max. © 1997 American Chemical Society.
Source Title: Industrial and Engineering Chemistry Research
URI: http://scholarbank.nus.edu.sg/handle/10635/91675
ISSN: 08885885
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.