Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.apenergy.2021.116936
Title: Reducing grid peak load through the coordinated control of battery energy storage systems located at electric vehicle charging parks
Authors: Kucevic, Daniel
Englberger, Stefan
Sharma, Anurag
Trivedi, Anupam 
Tepe, Benedikt
Schachler, Birgit
Hesse, Holger
Srinivasan, Dipti
Jossen, Andreas
Keywords: Battery energy storage system
Distribution grid
Electric vehicle charging
Grid integrated energy storage
Linear optimization
Lithium-ion
Peak load reduction
Issue Date: 1-Aug-2021
Publisher: Elsevier Ltd
Citation: Kucevic, Daniel, Englberger, Stefan, Sharma, Anurag, Trivedi, Anupam, Tepe, Benedikt, Schachler, Birgit, Hesse, Holger, Srinivasan, Dipti, Jossen, Andreas (2021-08-01). Reducing grid peak load through the coordinated control of battery energy storage systems located at electric vehicle charging parks. Applied Energy 295 : 116936. ScholarBank@NUS Repository. https://doi.org/10.1016/j.apenergy.2021.116936
Rights: Attribution 4.0 International
Abstract: Both global climate change and the decreasing cost of lithium-ion batteries are enablers of electric vehicles as an alternative form of transportation in the private sector. However, a high electric vehicle penetration in urban distribution grids leads to challenges, such as line over loading for the grid operator. In such a case installation of grid integrated storage systems represent an alternative to conventional grid reinforcement. This paper proposes a method of coordinated control for multiple battery energy storage systems located at electrical vehicle charging parks in a distribution grid using linear optimization in conjunction with time series modeling. The objective is to reduce the peak power at the point of common coupling in existing distribution grids with a high share of electric vehicles. An open source simulation tool has been developed that aims to couple a stand alone power flow model with a model of a stand alone battery energy storage system. This combination of previously disjointed tools enables more realistic simulation of the effects of storage systems in different operating modes on the distribution grid. Further information is derived from a detailed analysis of the storage system based on six key characteristics. The case study involves three charging parks with various sizes of coupled storage systems in a test grid in order to apply the developed method. By operating these storage systems using the coordinated control strategy, the maximum peak load can be reduced by 44.9%. The rise in peak load reduction increases linearly with small storage capacities, whereas saturation behavior can be observed above 800kWh. © 2021 The Authors
Source Title: Applied Energy
URI: https://scholarbank.nus.edu.sg/handle/10635/233306
ISSN: 0306-2619
DOI: 10.1016/j.apenergy.2021.116936
Rights: Attribution 4.0 International
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1016_j_apenergy_2021_116936.pdf2.06 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons