Title: Site Measurement and Study of Vertical Freezing Wall Temperatures of a Large-Diameter Shield Tunnel
Authors: Hu, J.
Liu, W.
Pan, Y. 
Zeng, H.
Issue Date: 2019
Publisher: Hindawi Limited
Citation: Hu, J., Liu, W., Pan, Y., Zeng, H. (2019). Site Measurement and Study of Vertical Freezing Wall Temperatures of a Large-Diameter Shield Tunnel. Advances in Civil Engineering 2019 : 8231458. ScholarBank@NUS Repository. https://doi.org/10.1155/2019/8231458
Rights: Attribution 4.0 International
Abstract: When a large-diameter shield tunnel boring machine enters or exits a tunnel, the newly exposed tunnel face is prone to instability and water seepage. In order to prevent collapse of the tunnel face, local ground improvement can be used until the permanent tunnel lining can be installed. The tunnel launching project of the Nanjing Metro Line 10 cross-river tunnel had a high stability requirement for the entry and exit phases. To this end, this project used a combination of cement treatment and ground freezing methods. In this project, field measurement of the vertical freezing improvement of the large-diameter shield tunnel was carried out. The temperature distribution and ground surface deformation of the vertical frozen soil wall at the end of the tunnel during the active freezing and maintenance freezing periods were analyzed in detail. The result shows that the surface settlement and seepage were successfully controlled by the combined cement treatment and ground freezing. On the other hand, the combination of cement treatment and ground freezing helps to control the freezing-induced heaving. The hydration heat in improved ground leads to an increase in ground temperature and this leads to additional freezing duration. It was examined that the frozen soil wall and the enclosure structure were in a good cementation condition. These measured values provide guidance on the timing of the shield departure. The project results confirmed that instability and water permeation did not occur in the tunnel face during the subsequent excavation. © 2019 Jun Hu et al.
Source Title: Advances in Civil Engineering
URI: https://scholarbank.nus.edu.sg/handle/10635/212499
ISSN: 1687-8086
DOI: 10.1155/2019/8231458
Rights: Attribution 4.0 International
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1155_2019_8231458.pdf3.27 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons