Please use this identifier to cite or link to this item: https://doi.org/10.9734/bjmmr/2016/27180
Title: Ease of Intubation with the McGRATH® MAC, C-MAC® or Macintosh Laryngoscopes by Novice Operators in Simulated Difficult Airways – A Manikin Study
Authors: Liew, L
Teo, W
Tan, B 
Leong, S
Tan, A 
Keywords: McGRATH® MAC
C- MAC®
video laryngoscopes
ease of intubation
Issue Date: 1-Jul-2016
Publisher: Sciencedomain International
Citation: Liew, L, Teo, W, Tan, B, Leong, S, Tan, A (2016-07-01). Ease of Intubation with the McGRATH® MAC, C-MAC® or Macintosh Laryngoscopes by Novice Operators in Simulated Difficult Airways – A Manikin Study. British Journal of Medicine and Medical Research 16 (8) : 1-6. ScholarBank@NUS Repository. https://doi.org/10.9734/bjmmr/2016/27180
Abstract: A variety of video laryngoscopes have been introduced to facilitate endotracheal intubations as failed intubations can result in morbidity and mortality. We aimed to compare the use of the conventional Macintosh laryngoscope, McGRATH® MAC and C- MAC® video laryngoscopes among novice operators. 37 medical students were recruited to perform oro-tracheal intubations in a human patient stimulator with simulated ‘difficult airway’ scenario using 3 devices: The Macintosh laryngoscope, McGRATH® MAC and C- MAC® video laryngoscopes. The success rate of tracheal intubation using the C-MAC® video laryngoscope (84%) was higher than both the McGRATH® MAC (59%) and the Macintosh laryngoscope (57%) (p=0.005). The use of video laryngoscopes were associated with lower incidence of oesophageal intubation (p<0.001) and deemed easier to use (p<0.001). Overall, the C-MAC® yielded a higher rate of successful tracheal intubation, a shorter time to glottic visualisation and was deemed to provide the greatest ease of intubation with novice practitioners.
Source Title: British Journal of Medicine and Medical Research
URI: https://scholarbank.nus.edu.sg/handle/10635/209048
ISSN: 22310614
DOI: 10.9734/bjmmr/2016/27180
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
View of Ease of Intubation with the McGRATH® MAC, C-MAC® or Macintosh Laryngoscopes by Novice Operators in Simulated Difficult Airways – A Manikin Study _ Journal of Advances in Medicine and Medical Research.pdf1.53 MBAdobe PDF

OPEN

PublishedView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.