Please use this identifier to cite or link to this item: https://doi.org/10.1364/BOE.402847
Title: Resolution enhancement and realistic speckle recovery with generative adversarial modeling of micro-optical coherence tomography
Authors: Liang, K.
Liu, X.
Chen, S.
Xie, J.
Lee, W.Q.
Liu, L.
Lee, H.K. 
Issue Date: 2020
Publisher: OSA - The Optical Society
Citation: Liang, K., Liu, X., Chen, S., Xie, J., Lee, W.Q., Liu, L., Lee, H.K. (2020). Resolution enhancement and realistic speckle recovery with generative adversarial modeling of micro-optical coherence tomography. Biomedical Optics Express 11 (12) : 7236-7252. ScholarBank@NUS Repository. https://doi.org/10.1364/BOE.402847
Rights: Attribution 4.0 International
Abstract: A resolution enhancement technique for optical coherence tomography (OCT), based on Generative Adversarial Networks (GANs), was developed and investigated. GANs have been previously used for resolution enhancement of photography and optical microscopy images. We have adapted and improved this technique for OCT image generation. Conditional GANs (cGANs) were trained on a novel set of ultrahigh resolution spectral domain OCT volumes, termed micro-OCT, as the high-resolution ground truth (?1 µm isotropic resolution). The ground truth was paired with a low-resolution image obtained by synthetically degrading resolution 4x in one of (1-D) or both axial and lateral axes (2-D). Cross-sectional image (B-scan) volumes obtained from in vivo imaging of human labial (lip) tissue and mouse skin were used in separate feasibility experiments. Accuracy of resolution enhancement compared to ground truth was quantified with human perceptual accuracy tests performed by an OCT expert. The GAN loss in the optimization objective, noise injection in both the generator and discriminator models, and multi-scale discrimination were found to be important for achieving realistic speckle appearance in the generated OCT images. The utility of high-resolution speckle recovery was illustrated by an example of micro-OCT imaging of blood vessels in lip tissue. Qualitative examples applying the models to image data from outside of the training data distribution, namely human retina and mouse bladder, were also demonstrated, suggesting potential for cross-domain transferability. This preliminary study suggests that deep learning generative models trained on OCT images from high-performance prototype systems may have potential in enhancing lower resolution data from mainstream/commercial systems, thereby bringing cutting-edge technology to the masses at low cost. © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Source Title: Biomedical Optics Express
URI: https://scholarbank.nus.edu.sg/handle/10635/199255
ISSN: 21567085
DOI: 10.1364/BOE.402847
Rights: Attribution 4.0 International
Appears in Collections:Staff Publications
Elements

Show full item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1364_BOE_402847.pdf6.06 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons