Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.chemosphere.2019.124804
Title: | A method to eliminate bromide interference on standard COD test for bromide-rich industrial wastewater | Authors: | Shi Xueqing Huang Shujuan Yeap Tsuey Shan Ong Say Leong Ng How Yong |
Keywords: | Bromide interference Bromide-rich industrial wastewater COD test Correction factor Masking agent |
Issue Date: | 2020 | Citation: | Shi Xueqing, Huang Shujuan, Yeap Tsuey Shan, Ong Say Leong, Ng How Yong (2020). A method to eliminate bromide interference on standard COD test for bromide-rich industrial wastewater. Chemosphere 240 : 124824. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chemosphere.2019.124804 | Abstract: | Chemical oxygen demand (COD) is one of the most important water quality parameters that quantifies the amount of oxygen needed to oxidize oxidizable pollutants (mainly organics) in water samples. However, erroneous COD results were commonly observed for bromide-rich industrial wastewater samples using standard COD test. Bromide in water sample is known to seriously interfere with COD test. However, there is no satisfactory approach to effectively eliminate bromide interference thus far. In this study, two strategies, namely masking and correction, were investigated for their effectiveness to suppress bromide interference. For the masking strategy, silver ion was assessed for its effectiveness to neutralize bromide in water samples through precipitation and complex formation reactions. Silver ion offered only partial masking effect on bromide, while the residue bromide can still cause significant interference on COD determination. For the correction strategy, an equivalent redox reaction reflecting bromide interference mechanism was proposed, and a theoretical correction factor of 0.1 g COD/g Br? was found based on stoichiometry. The effectiveness of the proposed correction factor for bromide interference under different wastewater pollutant matrix was evaluated using different types of wastewater samples (synthetic wastewater, domestic wastewater and bromide-rich industrial wastewater) with varying amounts of bromide (from 0 to 2000 mg L?1) added to the samples. The findings showed that with bromide concentration up to 600 mg L?1, the correction factor of 0.1 g COD/g Br? was applicable to all the tested wastewater samples, suggesting that this correction strategy could be practically used to eliminate bromide interference in standard COD test. © 2019 Elsevier Ltd | Source Title: | Chemosphere | URI: | https://scholarbank.nus.edu.sg/handle/10635/168170 | ISSN: | 0045-6535 1879-1298 |
DOI: | 10.1016/j.chemosphere.2019.124804 |
Appears in Collections: | Staff Publications Elements |
Show full item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
P2.2_AAM_A method to eliminate bromide interference on standard COD test for bromide-rich industrial wastewater.pdf | 800.82 kB | Adobe PDF | OPEN | Post-print | View/Download |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.