Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chemosphere.2019.124804
DC FieldValue
dc.titleA method to eliminate bromide interference on standard COD test for bromide-rich industrial wastewater
dc.contributor.authorShi Xueqing
dc.contributor.authorHuang Shujuan
dc.contributor.authorYeap Tsuey Shan
dc.contributor.authorOng Say Leong
dc.contributor.authorNg How Yong
dc.date.accessioned2020-05-15T02:09:12Z
dc.date.available2020-05-15T02:09:12Z
dc.date.issued2020
dc.identifier.citationShi Xueqing, Huang Shujuan, Yeap Tsuey Shan, Ong Say Leong, Ng How Yong (2020). A method to eliminate bromide interference on standard COD test for bromide-rich industrial wastewater. Chemosphere 240 : 124824. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chemosphere.2019.124804
dc.identifier.issn0045-6535
dc.identifier.issn1879-1298
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/168170
dc.description.abstractChemical oxygen demand (COD) is one of the most important water quality parameters that quantifies the amount of oxygen needed to oxidize oxidizable pollutants (mainly organics) in water samples. However, erroneous COD results were commonly observed for bromide-rich industrial wastewater samples using standard COD test. Bromide in water sample is known to seriously interfere with COD test. However, there is no satisfactory approach to effectively eliminate bromide interference thus far. In this study, two strategies, namely masking and correction, were investigated for their effectiveness to suppress bromide interference. For the masking strategy, silver ion was assessed for its effectiveness to neutralize bromide in water samples through precipitation and complex formation reactions. Silver ion offered only partial masking effect on bromide, while the residue bromide can still cause significant interference on COD determination. For the correction strategy, an equivalent redox reaction reflecting bromide interference mechanism was proposed, and a theoretical correction factor of 0.1 g COD/g Br? was found based on stoichiometry. The effectiveness of the proposed correction factor for bromide interference under different wastewater pollutant matrix was evaluated using different types of wastewater samples (synthetic wastewater, domestic wastewater and bromide-rich industrial wastewater) with varying amounts of bromide (from 0 to 2000 mg L?1) added to the samples. The findings showed that with bromide concentration up to 600 mg L?1, the correction factor of 0.1 g COD/g Br? was applicable to all the tested wastewater samples, suggesting that this correction strategy could be practically used to eliminate bromide interference in standard COD test. © 2019 Elsevier Ltd
dc.subjectBromide interference
dc.subjectBromide-rich industrial wastewater
dc.subjectCOD test
dc.subjectCorrection factor
dc.subjectMasking agent
dc.typeArticle
dc.contributor.departmentCIVIL AND ENVIRONMENTAL ENGINEERING
dc.description.doi10.1016/j.chemosphere.2019.124804
dc.description.sourcetitleChemosphere
dc.description.volume240
dc.description.page124824
dc.published.statePublished
dc.grant.idSembcorp-NUS Corporate Laboratory
dc.grant.fundingagencyNational Research Foundation
dc.grant.fundingagencySembcorp Industries Ltd.
dc.grant.fundingagencyNational University of Singapore
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
P2.2_AAM_A method to eliminate bromide interference on standard COD test for bromide-rich industrial wastewater.pdf800.82 kBAdobe PDF

OPEN

Post-printView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.