Please use this identifier to cite or link to this item:
https://doi.org/10.1097/PCC.0000000000000470
Title: | Ultrasound imaging reduces failure rates of percutaneous central venous catheterization in children | Authors: | Shime N. Hosokawa K. MacLaren G |
Keywords: | Anatomic Landmark Central Venous Catheterization Pediatrics Real Time Systematic Review Ultrasound |
Issue Date: | 2015 | Publisher: | Lippincott Williams and Wilkins | Citation: | Shime N., Hosokawa K., MacLaren G (2015). Ultrasound imaging reduces failure rates of percutaneous central venous catheterization in children. Pediatric Critical Care Medicine 16 (8) : 718-725. ScholarBank@NUS Repository. https://doi.org/10.1097/PCC.0000000000000470 | Abstract: | Objective: Ultrasound imaging has been shown to be beneficial for percutaneous central venous cannulation in systematic reviews of randomized controlled trials in adult patients, but not in pediatrics. The aim of this updated review was to determine whether percutaneous central venous catheterization with the aid of ultrasound reduces cannulation failure in children. Data Sources: PubMed was searched using the terms: ultrasound, catheterization, central vein (including internal jugular and femoral veins), and pediatrics. Study Selection: Both nonrandomized comparative studies and randomized controlled trials were eligible for inclusion if they assessed the rate of cannulation failure using real-time, dynamic ultrasound guidance, ultrasound-Assisted vein prelocation, and/or anatomic landmark technique. Data Extraction: Five nonrandomized studies and nine randomized controlled trials were included. The rates of cannulation failure and arterial puncture were retrieved. Data Synthesis: Random-effects meta-Analysis was applied. Conclusions: The meta-Analysis of five nonrandomized studies showed that the rate of cannulation failure was significantly lower with real-time ultrasound guidance than anatomic landmark technique (odds ratio, 0.44 [95% CI, 0.27-0.72]; p = 0.001). The combination of nine randomized controlled trials also showed lower failure rates with either the real-time ultrasound guidance or the prelocation technique over the landmark technique (odds ratio, 0.22 [95% CI, 0.07-0.69]; p = 0.0003) and fewer arterial punctures in the ultrasound group (odds ratio, 0.31 [95% CI, 0.09-1.08]; p = 0.07). However, seven out of nine studies were assessed as having high risk of bias. Since the lower cannulation failure and less frequent chance of arterial puncture with ultrasound were predominantly shown in studies at high risk of bias, further definitive and adequately powered studies with clear outcomes are needed. Copyright � 2015 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. | Source Title: | Pediatric Critical Care Medicine | URI: | https://scholarbank.nus.edu.sg/handle/10635/162658 | ISSN: | 15297535 | DOI: | 10.1097/PCC.0000000000000470 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.