Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/129206
Title: Comparative evaluation of two density gradient preparations for sperm separation for medically assisted conception
Authors: Chen, M.-J.
Bongso, A. 
Keywords: Percoll
Puresperm
PVP
Silane
Sperm separation
Issue Date: 1999
Citation: Chen, M.-J.,Bongso, A. (1999). Comparative evaluation of two density gradient preparations for sperm separation for medically assisted conception. Human Reproduction 14 (3) : 759-764. ScholarBank@NUS Repository.
Abstract: To evaluate and optimize the sperm separation efficiency of a novel silane-coated silica bead (Puresperm), serial studies were carried out to compare the various sperm parameters between: (i) three-layer (90%-70%-40%) Puresperm and three-layer (90%-70%-40%) conventional polyvinylpyrrolidone (PVP)-coated silica bead (Percoll) gradients; (ii) three-layer (90%-70%-40%) and two-layer (90%-45%) Puresperm gradients and separately the same for Percoll; and (iii) large (3.0 ml) and small (0.75 ml) semen loading volumes on three-layer Puresperm gradients. Normozoospermic semen samples were treated and analysed in 12 replicates for each experiment. Manual evaluation of concentration, percentage motility, percentage vitality, percentage normal morphology; computer-assisted semen analysis evaluation of concentration, percentage motility, grade of motility, motion characteristics (curvilinear velocity, linearity, amplitude of lateral head velocity, beat cross frequency, percentage hyperactivation); and yields from the initial semen samples were compared. Percoll was found to be superior to Puresperm in concentration, percentage motility, percentage vitality and yields after three-layer density gradient centrifugation. There were no significant differences in sperm parameters between two- and three-layer Percoll gradients, but three-layer Puresperm gradients behaved significantly better than two-layer gradients. Large semen volume loads on three-layer Puresperm gradients resulted in greater sperm concentrations, percentage motility, percentage vitality and percentage normal morphology, but small semen volume loads produced greater yields of good-quality spermatozoa. In the light of Percoll being withdrawn from the shelf for the use of assisted reproduction because of the presence of PVP, three-layer Puresperm gradients with large semen loading volumes appear to be an attractive alternative for sperm separation in medically assisted conception.
Source Title: Human Reproduction
URI: http://scholarbank.nus.edu.sg/handle/10635/129206
ISSN: 02681161
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.