Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.nimb.2012.10.033
DC FieldValue
dc.titleImproved beam spot measurements in the 2nd generation proton beam writing system
dc.contributor.authorYao, Y.
dc.contributor.authorVan Mourik, M.W.
dc.contributor.authorSanthana Raman, P.
dc.contributor.authorVan Kan, J.A.
dc.date.accessioned2014-10-16T09:28:38Z
dc.date.available2014-10-16T09:28:38Z
dc.date.issued2013
dc.identifier.citationYao, Y., Van Mourik, M.W., Santhana Raman, P., Van Kan, J.A. (2013). Improved beam spot measurements in the 2nd generation proton beam writing system. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms 306 : 265-270. ScholarBank@NUS Repository. https://doi.org/10.1016/j.nimb.2012.10.033
dc.identifier.issn0168583X
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/96879
dc.description.abstractNanosized ion beams (especially proton and helium) play a pivotal role in the field of ion beam lithography and ion beam analysis. Proton beam writing has shown lithographic details down to the 20 nm level, limited by the proton beam spot size. Introducing a smaller spot size will allow smaller lithographic features. Smaller probe sizes, will also drastically improve the spatial resolution for ion beam analysis techniques. Among many other requirements, having an ideal resolution standard, used for beam focusing and a reliable focusing method, is an important pre-requisite for sub-10 nm beam spot focusing. In this paper we present the fabrication processes of a free-standing resolution standard with reduced side-wall projection and high side-wall verticality. The resulting grid is orthogonal (90.0° ± 0.1), has smooth edges with better than 6 nm side-wall projection. The new resolution standard has been used in focusing a 2 MeV H2 + beam in the 2nd generation PBW system at Center for Ion Beam Applications, NUS. The beam size has been characterized using on- and off-axis scanning transmission ion microscopy (STIM) and ion induced secondary electron detection, carried out with a newly installed micro channel plate electron detector. The latter has been shown to be a realistic alternative to STIM measurements, as the drawback of PIN diode detector damage is alleviated. With these improvements we show reproducible beam focusing down to 14 nm. © 2012 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.nimb.2012.10.033
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentPHYSICS
dc.description.doi10.1016/j.nimb.2012.10.033
dc.description.sourcetitleNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
dc.description.volume306
dc.description.page265-270
dc.description.codenNIMBE
dc.identifier.isiut000321085900056
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.