Please use this identifier to cite or link to this item: https://doi.org/10.1111/j.1365-2818.2009.03352.x
DC FieldValue
dc.titleImaging using pulses: A simple and fast (>100 kHz) solution
dc.contributor.authorUdalagama, C.
dc.contributor.authorBettiol, A.A.
dc.contributor.authorWatt, F.
dc.date.accessioned2014-10-16T09:28:32Z
dc.date.available2014-10-16T09:28:32Z
dc.date.issued2010-05
dc.identifier.citationUdalagama, C., Bettiol, A.A., Watt, F. (2010-05). Imaging using pulses: A simple and fast (>100 kHz) solution. Journal of Microscopy 238 (2) : 185-188. ScholarBank@NUS Repository. https://doi.org/10.1111/j.1365-2818.2009.03352.x
dc.identifier.issn00222720
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/96870
dc.description.abstractImaging is an important component of spectroscopy. A good imaging system is expected to work with a high-pixel resolution using signals of high count-rates with as little dead time as possible to deliver an image quickly and reliably. It is not uncommon for such a system to be highly specialized, expensive and to consist of many dedicated electronic components. In this work, we present a simple imaging algorithm that can be used with a pulse (TTL) data signal, such as that produced by some photomultipliers and electron detectors. This algorithm works with only a simple general purpose data acquisition computer card (NI PXI/PCI-6259) from National Instruments residing in a computer. The system has been tested with signal rates in excess of 100 kHz to produce images at a pixel resolution of 512 × 512. The system's ability to handle such high count-rates hinges on utilizing the buffered data collection feature on the said card, in a hitherto unreported configuration. This system now offers a simple and cost-effective manner of incorporating high count-rate imaging features, such as in a scanning electron microscope, into a purely spectroscopic system. Further, since the use of the NI DAQ cards are supported under other computer platforms, the current imaging formalism is readily transferrable to computer platforms such as Linux or Mac OS. © 2009 The Royal Microscopical Society.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1111/j.1365-2818.2009.03352.x
dc.sourceScopus
dc.subjectFast Imaging
dc.subjectHigh count rates
dc.subjectSpectroscopy
dc.subjectTTL pulses
dc.typeArticle
dc.contributor.departmentPHYSICS
dc.description.doi10.1111/j.1365-2818.2009.03352.x
dc.description.sourcetitleJournal of Microscopy
dc.description.volume238
dc.description.issue2
dc.description.page185-188
dc.description.codenJMICA
dc.identifier.isiut000276793100009
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.