Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.bios.2004.08.005
DC FieldValue
dc.titleA glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode
dc.contributor.authorLim, S.H.
dc.contributor.authorWei, J.
dc.contributor.authorLin, J.
dc.contributor.authorLi, Q.
dc.contributor.authorKuaYou, J.
dc.date.accessioned2014-10-16T09:13:57Z
dc.date.available2014-10-16T09:13:57Z
dc.date.issued2005-05-15
dc.identifier.citationLim, S.H., Wei, J., Lin, J., Li, Q., KuaYou, J. (2005-05-15). A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode. Biosensors and Bioelectronics 20 (11) : 2341-2346. ScholarBank@NUS Repository. https://doi.org/10.1016/j.bios.2004.08.005
dc.identifier.issn09565663
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/95629
dc.description.abstractElectrodeposition was used for the co-deposition of glucose oxidase (GOx) enzymes and palladium nanoparticles onto a Nafion-solubilized carbon nanotube (CNT) film. The co-deposited Pd-GOx-Nafion CNT bioelectrode retains its biocatalytic activity and offers an efficient oxidation and reduction of the enzymatically liberated H2O2, allowing for fast and sensitive glucose quantification. The combination of Pd-GOx electrodeposition with Nafion-solubilized CNTs enhances the storage time and performance of the sensor. An extra Nafion coating was used to eliminate common interferents such as uric and ascorbic acids. The fabricated Pd-GOx-Nafion CNT glucose biosensor exhibits a linear response up to 12 mM glucose and a detection limit of 0.15 mM (S/N = 3). © 2004 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.bios.2004.08.005
dc.sourceScopus
dc.subjectElectrodeposition
dc.subjectNafion
dc.subjectPalladium nanoparticles
dc.typeArticle
dc.contributor.departmentPHYSICS
dc.description.doi10.1016/j.bios.2004.08.005
dc.description.sourcetitleBiosensors and Bioelectronics
dc.description.volume20
dc.description.issue11
dc.description.page2341-2346
dc.description.codenBBIOE
dc.identifier.isiut000228827000023
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

285
checked on Feb 1, 2023

WEB OF SCIENCETM
Citations

274
checked on Feb 1, 2023

Page view(s)

379
checked on Feb 2, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.