DC Field | Value | |
---|---|---|
dc.title | A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode | |
dc.contributor.author | Lim, S.H. | |
dc.contributor.author | Wei, J. | |
dc.contributor.author | Lin, J. | |
dc.contributor.author | Li, Q. | |
dc.contributor.author | KuaYou, J. | |
dc.date.accessioned | 2014-10-16T09:13:57Z | |
dc.date.available | 2014-10-16T09:13:57Z | |
dc.date.issued | 2005-05-15 | |
dc.identifier.citation | Lim, S.H., Wei, J., Lin, J., Li, Q., KuaYou, J. (2005-05-15). A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode. Biosensors and Bioelectronics 20 (11) : 2341-2346. ScholarBank@NUS Repository. https://doi.org/10.1016/j.bios.2004.08.005 | |
dc.identifier.issn | 09565663 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/95629 | |
dc.description.abstract | Electrodeposition was used for the co-deposition of glucose oxidase (GOx) enzymes and palladium nanoparticles onto a Nafion-solubilized carbon nanotube (CNT) film. The co-deposited Pd-GOx-Nafion CNT bioelectrode retains its biocatalytic activity and offers an efficient oxidation and reduction of the enzymatically liberated H2O2, allowing for fast and sensitive glucose quantification. The combination of Pd-GOx electrodeposition with Nafion-solubilized CNTs enhances the storage time and performance of the sensor. An extra Nafion coating was used to eliminate common interferents such as uric and ascorbic acids. The fabricated Pd-GOx-Nafion CNT glucose biosensor exhibits a linear response up to 12 mM glucose and a detection limit of 0.15 mM (S/N = 3). © 2004 Elsevier B.V. All rights reserved. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.bios.2004.08.005 | |
dc.source | Scopus | |
dc.subject | Electrodeposition | |
dc.subject | Nafion | |
dc.subject | Palladium nanoparticles | |
dc.type | Article | |
dc.contributor.department | PHYSICS | |
dc.description.doi | 10.1016/j.bios.2004.08.005 | |
dc.description.sourcetitle | Biosensors and Bioelectronics | |
dc.description.volume | 20 | |
dc.description.issue | 11 | |
dc.description.page | 2341-2346 | |
dc.description.coden | BBIOE | |
dc.identifier.isiut | 000228827000023 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.