Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.bios.2004.08.005
DC FieldValue
dc.titleA glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode
dc.contributor.authorLim, S.H.
dc.contributor.authorWei, J.
dc.contributor.authorLin, J.
dc.contributor.authorLi, Q.
dc.contributor.authorKuaYou, J.
dc.date.accessioned2014-10-16T09:13:57Z
dc.date.available2014-10-16T09:13:57Z
dc.date.issued2005-05-15
dc.identifier.citationLim, S.H., Wei, J., Lin, J., Li, Q., KuaYou, J. (2005-05-15). A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode. Biosensors and Bioelectronics 20 (11) : 2341-2346. ScholarBank@NUS Repository. https://doi.org/10.1016/j.bios.2004.08.005
dc.identifier.issn09565663
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/95629
dc.description.abstractElectrodeposition was used for the co-deposition of glucose oxidase (GOx) enzymes and palladium nanoparticles onto a Nafion-solubilized carbon nanotube (CNT) film. The co-deposited Pd-GOx-Nafion CNT bioelectrode retains its biocatalytic activity and offers an efficient oxidation and reduction of the enzymatically liberated H2O2, allowing for fast and sensitive glucose quantification. The combination of Pd-GOx electrodeposition with Nafion-solubilized CNTs enhances the storage time and performance of the sensor. An extra Nafion coating was used to eliminate common interferents such as uric and ascorbic acids. The fabricated Pd-GOx-Nafion CNT glucose biosensor exhibits a linear response up to 12 mM glucose and a detection limit of 0.15 mM (S/N = 3). © 2004 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.bios.2004.08.005
dc.sourceScopus
dc.subjectElectrodeposition
dc.subjectNafion
dc.subjectPalladium nanoparticles
dc.typeArticle
dc.contributor.departmentPHYSICS
dc.description.doi10.1016/j.bios.2004.08.005
dc.description.sourcetitleBiosensors and Bioelectronics
dc.description.volume20
dc.description.issue11
dc.description.page2341-2346
dc.description.codenBBIOE
dc.identifier.isiut000228827000023
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.