Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chroma.2006.08.006
DC FieldValue
dc.titleIon-pair dynamic liquid-phase microextraction combined with injection-port derivatization for the determination of long-chain fatty acids in water samples
dc.contributor.authorWu, J.
dc.contributor.authorLee, H.K.
dc.date.accessioned2014-10-16T08:32:11Z
dc.date.available2014-10-16T08:32:11Z
dc.date.issued2006-11-10
dc.identifier.citationWu, J., Lee, H.K. (2006-11-10). Ion-pair dynamic liquid-phase microextraction combined with injection-port derivatization for the determination of long-chain fatty acids in water samples. Journal of Chromatography A 1133 (1-2) : 13-20. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chroma.2006.08.006
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/94105
dc.description.abstractIon-pair dynamic liquid-phase microextraction coupled to injection-port derivatization has been developed for the determination of long-chain fatty acids in water samples by gas chromatography-mass spectrometry (GC-MS). In this procedure, long-chain fatty acids (C14, C16 and C18) were converted into their ion-pair complexes with tetrabutylammonium hydrogen sulfate and then extracted by organic solvent (1-octanol) impregnated in the hollow fiber. The dynamic nature of the extraction was represented by the repeated movement of the acceptor phase (organic solvent) in the hollow fiber that was controlled by a syringe pump. Ion pairs of fatty acids quantitatively formed butyl esters in the injection-port of the gas chromatography. Several parameters such as injection temperature, purge-off time, organic solvent, ion-pair reagent, pH, agitation speed, extraction time and the syringe pump parameters (plunger speed and dwell time) have been optimized. The limits of detection were in the range 0.0093-0.015 ng mL-1 (at a signal-to-noise ratio of 3) under GC-MS-selected ion monitoring mode and the relative standard deviations were between 7.7% and 11.5%. The method was successfully applied to measure long-chain fatty acids in real water samples. © 2006 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.chroma.2006.08.006
dc.sourceScopus
dc.subjectDynamic extraction
dc.subjectFatty acids
dc.subjectGas chromatography-mass spectrometry
dc.subjectHollow fiber membranes
dc.subjectInjection-port derivatization
dc.subjectIon-pair extraction
dc.subjectLiquid-phase microextraction
dc.subjectWater analysis
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/j.chroma.2006.08.006
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume1133
dc.description.issue1-2
dc.description.page13-20
dc.description.codenJCRAE
dc.identifier.isiut000241772800002
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.