Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.chroma.2011.12.110
DC Field | Value | |
---|---|---|
dc.title | Ionic liquid based hollow fiber supported liquid phase microextraction of ultraviolet filters | |
dc.contributor.author | Ge, D. | |
dc.contributor.author | Lee, H.K. | |
dc.date.accessioned | 2014-10-16T08:32:05Z | |
dc.date.available | 2014-10-16T08:32:05Z | |
dc.date.issued | 2012-03-16 | |
dc.identifier.citation | Ge, D., Lee, H.K. (2012-03-16). Ionic liquid based hollow fiber supported liquid phase microextraction of ultraviolet filters. Journal of Chromatography A 1229 : 1-5. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chroma.2011.12.110 | |
dc.identifier.issn | 00219673 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/94099 | |
dc.description.abstract | Hollow fiber protected liquid phase microextraction using an ionic liquid as supported phase and acceptor phase (IL-HF-LPME) is proposed for the determination of four ultraviolet (UV) filters (benzophenone, 3-(4-methylbenzylidene)-camphor, 2-hydroxy-4-methoxybenzophenone and 2,4-dihydroxybenzophenone) in water samples for the first time. In the present study, four different ILs 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate) [HMIM][FAP], 1-butyl-1-methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate [BMPL][FAP], 1-butyl-3-methylimidazolium phosphate ([BMIM][PO 4]) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF 6]) were evaluated as extraction solvent. Only [HMIM][FAP] showed high chemical affinity to the analytes which permits a selective isolation of the UV filters from the sample matrix, allowing also their preconcentration. IL-HF-LPME and high performance liquid chromatography provides repeatability from 1.1% to 8.2% and limits of detection between 0.3 and 0.5ng/ml. Real water samples spiked with the analytes extracted were analyzed, and yielded relative recoveries ranging from 82.6% to 105.9%. © 2012 Elsevier B.V. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.chroma.2011.12.110 | |
dc.source | Scopus | |
dc.subject | Hollow fiber supported liquid phase microextraction | |
dc.subject | Ionic liquid | |
dc.subject | UV filters | |
dc.subject | Water analysis | |
dc.type | Article | |
dc.contributor.department | CHEMISTRY | |
dc.description.doi | 10.1016/j.chroma.2011.12.110 | |
dc.description.sourcetitle | Journal of Chromatography A | |
dc.description.volume | 1229 | |
dc.description.page | 1-5 | |
dc.description.coden | JCRAE | |
dc.identifier.isiut | 000301606600001 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.