Please use this identifier to cite or link to this item:
https://doi.org/10.1016/S0003-2670(01)01396-4
DC Field | Value | |
---|---|---|
dc.title | Differential pulse voltammetric determination of trace Te(IV) at a poly(3,3′-diaminobenzidine) film modified gold electrode in flow systems | |
dc.contributor.author | Khoo, S.B. | |
dc.contributor.author | Ye, R. | |
dc.date.accessioned | 2014-10-16T08:26:03Z | |
dc.date.available | 2014-10-16T08:26:03Z | |
dc.date.issued | 2002-02-25 | |
dc.identifier.citation | Khoo, S.B., Ye, R. (2002-02-25). Differential pulse voltammetric determination of trace Te(IV) at a poly(3,3′-diaminobenzidine) film modified gold electrode in flow systems. Analytica Chimica Acta 453 (2) : 209-220. ScholarBank@NUS Repository. https://doi.org/10.1016/S0003-2670(01)01396-4 | |
dc.identifier.issn | 00032670 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/93588 | |
dc.description.abstract | Electropolymerization of 3,3′-diaminobenzidine on a gold surface gave an adherent, stable film of poly(3,3′-diaminobenzidine) (PDAB). This polymer film retained the complexational functionalities of its monomer, demonstrating preconcentration abilities for several ions, including Se(IV) and Te(IV). In particular, in this work, continuous flow and flow injection methods were developed for the sensitive and selective determination of Te(IV). The optimized method for the continuous flow mode had a detection limit of 5.6 × 10-9 moll-1 for 10min preconcentration. Typical relative standard deviations for six consecutive determinations were 1.82 and 2.56% for Te(IV) concentrations of 1.0 × 10-6 and 5.0 × 10-8 moll-1, respectively (10min preconcentration). The method was applied to the determination of Te(IV) in real samples. © 2002 Elsevier Science B.V. All rights reserved. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0003-2670(01)01396-4 | |
dc.source | Scopus | |
dc.subject | Differential pulse anodic voltammetry | |
dc.subject | Flow methods | |
dc.subject | Gold electrode | |
dc.subject | Medium exchange | |
dc.subject | Poly(3,3′-diaminobenzidine) film | |
dc.subject | Trace tellurium determination | |
dc.type | Article | |
dc.contributor.department | CHEMISTRY | |
dc.description.doi | 10.1016/S0003-2670(01)01396-4 | |
dc.description.sourcetitle | Analytica Chimica Acta | |
dc.description.volume | 453 | |
dc.description.issue | 2 | |
dc.description.page | 209-220 | |
dc.description.coden | ACACA | |
dc.identifier.isiut | 000173946300006 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.