Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chroma.2005.05.077
DC FieldValue
dc.titleAutomated dynamic liquid-liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection for the determination of phenoxy acid herbicides in environmental waters
dc.contributor.authorWu, J.
dc.contributor.authorKim, H.E.
dc.contributor.authorHian, K.L.
dc.date.accessioned2014-10-16T08:21:06Z
dc.date.available2014-10-16T08:21:06Z
dc.date.issued2005-08-05
dc.identifier.citationWu, J., Kim, H.E., Hian, K.L. (2005-08-05). Automated dynamic liquid-liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection for the determination of phenoxy acid herbicides in environmental waters. Journal of Chromatography A 1082 (2) : 121-127. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chroma.2005.05.077
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/93159
dc.description.abstractAutomated dynamic liquid-liquid-liquid microextraction (D-LLLME) controlled by a programmable syringe pump and combined with HPLC-UV was investigated for the extraction and determination of 5 phenoxy acid herbicides in aqueous samples. In the extraction procedure, the acceptor phase was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. The repetitive movement of acceptor phase into and out of the hollow fiber channel facilitated the transfer of analytes into donor phase, from the organic phase held in the pore of the fiber. Parameters such as the organic solvent, concentrations of the donor and acceptor phases, plunger movement pattern, speed of agitation and ionic strength of donor phase were evaluated. Good linearity of analytes was achieved in the range of 0.5-500 ng/ml with coefficients of determination, r2 > 0.9994. Good repeatabilities of extraction performance were obtained with relative standard deviations lower than 7.5%. The method provided up-to 490-fold enrichment within 13 min. In addition, the limits of detection (LODs) ranged from 0.1 to 0.4 ng/mL (S/N = 3). D-LLLME was successfully applied for the analysis of phenoxy acid herbicides from real environmental water samples. © 2005 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.chroma.2005.05.077
dc.sourceScopus
dc.subjectAutomation
dc.subjectDynamic extraction
dc.subjectHollow fiber membranes
dc.subjectLiquid-liquid-liquid microextraction
dc.subjectLiquid-phase microextraction
dc.subjectPhenoxy acid herbicides
dc.subjectWater analysis
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/j.chroma.2005.05.077
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume1082
dc.description.issue2
dc.description.page121-127
dc.description.codenJCRAE
dc.identifier.isiut000230368200001
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.