Please use this identifier to cite or link to this item: https://doi.org/10.1002/chir.22074
DC FieldValue
dc.titleA new biosensor for chiral recognition using goat and rabbit serum albumin self-assembled quartz crystal microbalance
dc.contributor.authorChen, W.-J.
dc.contributor.authorZhang, S.
dc.contributor.authorZhang, W.-G.
dc.contributor.authorFan, J.
dc.contributor.authorYin, X.
dc.contributor.authorZheng, S.-R.
dc.contributor.authorSu, W.-C.
dc.contributor.authorZhang, Z.
dc.contributor.authorHong, T.
dc.date.accessioned2014-10-16T08:18:45Z
dc.date.available2014-10-16T08:18:45Z
dc.date.issued2012-10
dc.identifier.citationChen, W.-J., Zhang, S., Zhang, W.-G., Fan, J., Yin, X., Zheng, S.-R., Su, W.-C., Zhang, Z., Hong, T. (2012-10). A new biosensor for chiral recognition using goat and rabbit serum albumin self-assembled quartz crystal microbalance. Chirality 24 (10) : 804-809. ScholarBank@NUS Repository. https://doi.org/10.1002/chir.22074
dc.identifier.issn08990042
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/92960
dc.description.abstractQuartz crystal microbalance (QCM) biosensor was used for the chiral recognition of five pairs of enantiomers by using goat serum albumin (GSA) and rabbit serum albumin (RbSA) as chiral selectors. Serum albumin (SA) was immobilized on the QCM through the self-assembled monolayer technique, and the surface concentration of GSA and RbSA were 8.8 × 10-12 mol cm-2 and 1.2 × 10-11 mol cm-2, respectively. The QCM biosensors showed excellent sensitivity and selectivity. Meanwhile, the chiral recognition of SA sensors was quite species dependent. There were differences between GSA and RbSA sensors in the ability and the preference of chiral recognition. To R,S-1,2,3,4-tetrahydro-1-naphthylamine (R,S-1-TNA), R,S-1-(4-methoxyphenyl)ethylamine (R,S-4-MPEA), and R,S-1-(3-methoxyphenyl)ethylamine (R,S-3-MPEA), the preference of the stereoselective SA-drug binding of the two kinds of SA sensors were consistent. However, to R,S-2-octanol (R, S-2-OT) and R,S-methyl lactate (R,S-MEL), the two kinds of SA sensors had opposite chiral recognition preference. Moreover, the interactions of SA and the five pairs of enantiomers have been further investigated through ultraviolet (UV) and fluorescent (FL) spectra. The UV/FL results were in accordance with the consequence of QCM. Copyright © 2012 Wiley Periodicals, Inc.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1002/chir.22074
dc.sourceScopus
dc.subjectbiosensor
dc.subjectchiral recognition
dc.subjectQCM
dc.subjectserum albumin
dc.subjectUV/FL spectra
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1002/chir.22074
dc.description.sourcetitleChirality
dc.description.volume24
dc.description.issue10
dc.description.page804-809
dc.description.codenCHRLE
dc.identifier.isiut000309240200006
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.