Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.memsci.2006.12.036
Title: | Tailoring pore size and pore size distribution of kidney dialysis hollow fiber membranes via dual-bath coagulation approach | Authors: | Yang, Q. Chung, T.-S. Santoso, Y.E. |
Keywords: | Dual-bath coagulation Kidney dialysis membrane NaOCl treatment PES hollow fiber membrane Pore size and pore size distribution |
Issue Date: | 1-Apr-2007 | Citation: | Yang, Q., Chung, T.-S., Santoso, Y.E. (2007-04-01). Tailoring pore size and pore size distribution of kidney dialysis hollow fiber membranes via dual-bath coagulation approach. Journal of Membrane Science 290 (1-2) : 153-163. ScholarBank@NUS Repository. https://doi.org/10.1016/j.memsci.2006.12.036 | Abstract: | Polyethersulfone (PES) hollow fiber membranes for kidney dialysis application were prepared by the dry-jet wet-spinning method. A dual-coagulation bath technology was first time employed for fabricating the kidney dialysis membranes with a tight inner skin and loose outer supporting layer structure. A weak coagulant isopropanol (IPA) was served as the first external coagulation bath, while water as the second bath. Experiments demonstrate their advantages of better controlling both inner and outer skin morphology. The as-spun fibers have a higher mean effective pore size (μp), pure water permeation flux (PWP) and molecular weight cut-off (MWCO) with an increase in N-methyl-2-pyrrolidone (NMP) percentage in bore fluid (i.e., internal coagulant). After being treated in 8000 ppm NaOCl solution for 1 day, fibers show larger pore sizes and porosity in both inner and outer surfaces, and thinner inner and outer layers than their as-spun counterparts. Among them, the bleached fibers spun with 50 wt.% NMP in bore fluid have the MWCO (43 kDa) and PWP (40 × 10-5 L m-2 Pa-1 h-1) suitable for kidney dialysis application. Based on SEM observations and solute rejection performance, the further heat treated fibers in an aqueous solution is found to be an effective way to fine tune membranes morphology and MWCO for kidney dialysis application. The solute rejection performance data of the hollow fiber membranes spun with 55 wt.% NMP in bore fluid after heat treated at 90 °C in water for 2 h were found to be very appropriate for the kidney dialysis application. © 2007 Elsevier B.V. All rights reserved. | Source Title: | Journal of Membrane Science | URI: | http://scholarbank.nus.edu.sg/handle/10635/90297 | ISSN: | 03767388 | DOI: | 10.1016/j.memsci.2006.12.036 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.