Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.memsci.2005.04.034
DC FieldValue
dc.titleFabrication and characterization of BTDA-TDI/MDI (P84) co-polyimide membranes for the pervaporation dehydration of isopropanol
dc.contributor.authorQiao, X.
dc.contributor.authorChung, T.-S.
dc.contributor.authorPramoda, K.P.
dc.date.accessioned2014-10-09T06:47:29Z
dc.date.available2014-10-09T06:47:29Z
dc.date.issued2005-11-01
dc.identifier.citationQiao, X., Chung, T.-S., Pramoda, K.P. (2005-11-01). Fabrication and characterization of BTDA-TDI/MDI (P84) co-polyimide membranes for the pervaporation dehydration of isopropanol. Journal of Membrane Science 264 (1-2) : 176-189. ScholarBank@NUS Repository. https://doi.org/10.1016/j.memsci.2005.04.034
dc.identifier.issn03767388
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/88888
dc.description.abstractAsymmetric membranes with superior selectivity and relatively high flux for pervaporative dehydration of isopropanol (IPA) were successfully developed from a novel material P84 co-polyimide by a dry-wet phase inversion method. The best separation performance has a flux of 432 g/m2 h and a separation factor of 3508 at 60°C for a feed stream containing 85 wt.% IPA. The membrane shows imperceptible degree of swelling even at high feed water concentrations. Polymer dopes with or without non-solvent additives were studied and yielded different membrane skin layer structure. It is found that heat treatment at elevated temperatures can effectively enhance membrane performance because it not only smoothens membrane skin layer roughness but also reduces membrane defects and the d-space value of polymeric chains as indicated by XRD, FESEM, AFM and gas permeation tests. However, asymmetric P84 co-polyimide membranes' performance was influenced by the history of thermal cycling. The testing cycle from 100°C to 60°C has a more stable performance compared with that from 60°C to 100°C, indicating that a conditioning at a higher temperature is recommended. Thickness-dependent pervaporation performance was observed when investigating dense P84 membranes, and the pervaporation data from asymmetric P84 membranes are consistent with this observation. © 2005 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.memsci.2005.04.034
dc.sourceScopus
dc.subjectAsymmetric membrane
dc.subjectDehydration
dc.subjectIsopropanol
dc.subjectP84 co-polyimide
dc.subjectPervaporation
dc.typeArticle
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.description.doi10.1016/j.memsci.2005.04.034
dc.description.sourcetitleJournal of Membrane Science
dc.description.volume264
dc.description.issue1-2
dc.description.page176-189
dc.description.codenJMESD
dc.identifier.isiut000232756400020
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.