Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.talanta.2005.08.060
DC FieldValue
dc.titleOptimization and validation of a low temperature microwave-assisted extraction method for analysis of polycyclic aromatic hydrocarbons in airborne particulate matter
dc.contributor.authorKarthikeyan, S.
dc.contributor.authorBalasubramanian, R.
dc.contributor.authorSee, S.W.
dc.date.accessioned2014-10-08T08:33:05Z
dc.date.available2014-10-08T08:33:05Z
dc.date.issued2006-03-15
dc.identifier.citationKarthikeyan, S., Balasubramanian, R., See, S.W. (2006-03-15). Optimization and validation of a low temperature microwave-assisted extraction method for analysis of polycyclic aromatic hydrocarbons in airborne particulate matter. Talanta 69 (1) : 79-86. ScholarBank@NUS Repository. https://doi.org/10.1016/j.talanta.2005.08.060
dc.identifier.issn00399140
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/87572
dc.description.abstractA low temperature microwave-assisted extraction method (MAE) is reported for the analysis of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter (PM). The main parameters affecting the extraction efficiency (choice of extractants, microwave power, and extraction time) were investigated and optimized. The optimized procedure requires a 20 ml mixture of acetone:n-hexane (1:1) for extraction of PAHs in PM at 150 W of microwave energy (20 min extraction time). Clean-up of MAE extracts was not found to be necessary. The optimized method was validated using two different SRM (1648-urban particulate matter and 1649a, urban dust). The results obtained are in good agreement with certified values. PAHs recoveries for both reference materials were between 79 and 122% with relative standard deviation ranging from 3 to 21%. Detection limits were determined based on blank determination using two kinds of quartz filter substrates (n = 10), which ranged from 0.001 (0.03) ng m-3 (pg/μg) for B(k)Ft to 1.119 (37.3) for Naph in ng m -3 (pg/μg), respectively. The repeatability and day-to-day reproducibility obtained in this study were in the range of 4-16 and 3-25% for spiked standards and SRM 1649, respectively. The optimized and validated MAE technique was applied to the extraction of PAHs from a set of real world PM samples collected in Singapore. The sum of particulate-bound PAHs in outdoor PM ranged from 1.05 to 3.45 ng m-3 while that in indoor PM (cooking emissions) ranged from 27.6 to 75.7 ng m-3, respectively. © 2005 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.talanta.2005.08.060
dc.sourceScopus
dc.subjectAir pollution
dc.subjectAirborne particulate matter (PM)
dc.subjectCooking
dc.subjectMicrowave-assisted extraction (MAE)
dc.subjectPolycyclic aromatic hydrocarbons (PAHs)
dc.typeArticle
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.contributor.departmentDIVISION OF ENVIRONMENTAL SCIENCE & ENGG
dc.description.doi10.1016/j.talanta.2005.08.060
dc.description.sourcetitleTalanta
dc.description.volume69
dc.description.issue1
dc.description.page79-86
dc.description.codenTLNTA
dc.identifier.isiut000235510000012
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.