Title: Performance of different photovoltaic cells operating under the meteorological conditions of Singapore
Authors: Hawladera, M.N.A.
Seng, L.P. 
Kiang, C.K.
Keywords: conversion efficiency
mono-crystalline
poly-crystalline
power generation
PV performance
solar fraction
tandem cells
Issue Date: 2012
Citation: Hawladera, M.N.A., Seng, L.P., Kiang, C.K. (2012). Performance of different photovoltaic cells operating under the meteorological conditions of Singapore. AIP Conference Proceedings 1440 : 1003-1011. ScholarBank@NUS Repository. https://doi.org/10.1063/1.4704315
Abstract: Three different types of photovoltaic solar cells were installed and connected in grid-tie inverters to run a blower or pump under the meteorological conditions of Singapore. Experiments were performed over a period of time, where all three types of cells, each type having a rated power of 360W, were exposed to same environmental conditions. For a day with a maximum irradiation of about 760Wm-2, analyses of data to determine the performance of solar cells revealed an average efficiency of mono crystalline, poly crystalline and tandem cells of about 10.4%, 9.5% and 8.8%, respectively. The maximum efficiencies recorded were 14.5% for mono-crystalline, 13.5% for polycrystalline and 11% for tandem cells. Although tandem cell has the lowest average efficiency, it shows the highest Solar Fraction (SF) compared to mono and poly crystalline cells. The electricity production of mono crystalline, poly crystalline and tandem cell for 30 consecutive days shows that tandem cell has the highest production with an average value of 1.7KWh. The total production of mono and poly crystalline cell is approximately the same. Both of them have the average daily value of about 1.5KWh. On a day, with irradiation of about 760Wm-2 and without any cooling, the surface temperature of mono-crystalline, poly-crystalline and tandem cell were 59°C, 58.4°C and 57.7°C, respectively. On the other hand, the surface temperature has only reached 35.5°C, 35.1°C, 33.6°C, respectively, when the first data was recorded in the early morning, when the irradiation was about 450Wm -2. As the efficiency of the cell is dependent upon operating temperature, appropriate measures should be undertaken to maintain low operating temperature, particularly, when the irradiation is high. © 2012 American Institute of Physics.
Source Title: AIP Conference Proceedings
URI: http://scholarbank.nus.edu.sg/handle/10635/86050
ISBN: 9780735410329
ISSN: 0094243X
DOI: 10.1063/1.4704315
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.