Please use this identifier to cite or link to this item: https://doi.org/10.1007/s00397-002-0262-y
DC FieldValue
dc.titleUsing oscillatory squeezing flow to measure the viscoelastic properties of dental composite resin cements during curing
dc.contributor.authorJiang, P.
dc.contributor.authorSee, H.
dc.contributor.authorSwain, M.V.
dc.contributor.authorPhan-Thien, N.
dc.date.accessioned2014-10-07T09:12:38Z
dc.date.available2014-10-07T09:12:38Z
dc.date.issued2003-01
dc.identifier.citationJiang, P., See, H., Swain, M.V., Phan-Thien, N. (2003-01). Using oscillatory squeezing flow to measure the viscoelastic properties of dental composite resin cements during curing. Rheologica Acta 42 (1) : 118-122. ScholarBank@NUS Repository. https://doi.org/10.1007/s00397-002-0262-y
dc.identifier.issn00354511
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/85824
dc.description.abstractWe have investigated the rheological changes in two particulate-filled dental composite resin cements during the curing process using a Micro-Fourier Rheometer (MFR). In the MFR, the sample was sandwiched between two parallel plates, and pseudorandom small amplitude squeezing was applied by oscillating the upper plate over a range of frequencies. Fourier transforms of the displacement signal and the resulting time dependent force signal enabled the rapid determination of the dynamic properties G′ and G″ over the frequency range 2π-200π rad/s. This technique permitted us to follow changes in the rheological properties of the resin cements through the setting period. A typical result was that G′ increased from 2×103 Pa to 2×105 Pa after about 120 s, and that G″ changed from 4×103 Pa to 4×104 Pa over the same period at frequency 40π rad/s. We also found that the dental composite resin cements show linear viscoelastic behaviour over a range of strain amplitudes before curing, but the response becomes distinctly non-linear at the later stages of curing for strain amplitudes γ > 0.067%.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1007/s00397-002-0262-y
dc.sourceScopus
dc.subjectCuring
dc.subjectDental resin cements
dc.subjectMicro-Fourier rheometer
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1007/s00397-002-0262-y
dc.description.sourcetitleRheologica Acta
dc.description.volume42
dc.description.issue1
dc.description.page118-122
dc.identifier.isiut000180808400012
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.