Please use this identifier to cite or link to this item: https://doi.org/10.1080/19443994.2012.714580
DC FieldValue
dc.titleThe performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit
dc.contributor.authorMyat, A.
dc.contributor.authorThu, K.
dc.contributor.authorKim, Y.D.
dc.contributor.authorChoon, N.K.
dc.date.accessioned2014-10-07T09:12:00Z
dc.date.available2014-10-07T09:12:00Z
dc.date.issued2013
dc.identifier.citationMyat, A., Thu, K., Kim, Y.D., Choon, N.K. (2013). The performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit. Desalination and Water Treatment 51 (7-9) : 1900-1907. ScholarBank@NUS Repository. https://doi.org/10.1080/19443994.2012.714580
dc.identifier.issn19443994
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/85774
dc.description.abstractThis paper presents the performance investigation of a temperature cascaded cogeneration plant, shortly in TCCP, equipped with an efficient waste heat recovery system. The TCCP or cogeneration system produces four types of useful energy namely (i) electricity, (ii) steam, (iii) cooling, and (iv) dehumidification and distilled water by utilizing single energy source. The TCCP comprises a Capstone C30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heatactivated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption desalination system, and (iv) a multi-bed desiccant dehumidifier. The analysis is performed under different operation conditions such as heat source temperatures, flow rates of heat transfer fluids and chilled water inlet temperatures. The only single heat source for TCCP is obtained from exhaust gas of micro-turbine and it is channeled to a series of waste heat recovery heat exchangers to steam and hot water at different temperatures. Hot water produced by such a compact heat exchangers is the driving heat source to produce steam of 15 kg/h, cooling of 2 Rton, dehumidification of 2 Rton, and distilled water of 0.7 m3/day. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor could achieve as high as 70% while fuel energy saving ratio is found to be 28%. © 2013 Desalination Publications. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1080/19443994.2012.714580
dc.sourceScopus
dc.subjectAdsorption desalination
dc.subjectCogeneration
dc.subjectEnergy utilization factor
dc.subjectTemperature cascaded
dc.subjectWaste heat recovery
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1080/19443994.2012.714580
dc.description.sourcetitleDesalination and Water Treatment
dc.description.volume51
dc.description.issue7-9
dc.description.page1900-1907
dc.identifier.isiut000313795500068