Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.applthermaleng.2012.01.041
DC FieldValue
dc.titleThe experimental investigation on the performance of a low temperature waste heat-driven multi-bed desiccant dehumidifier (MBDD) and minimization of entropy generation
dc.contributor.authorMyat, A.
dc.contributor.authorThu, K.
dc.contributor.authorChoon, N.K.
dc.date.accessioned2014-10-07T09:11:53Z
dc.date.available2014-10-07T09:11:53Z
dc.date.issued2012-06
dc.identifier.citationMyat, A., Thu, K., Choon, N.K. (2012-06). The experimental investigation on the performance of a low temperature waste heat-driven multi-bed desiccant dehumidifier (MBDD) and minimization of entropy generation. Applied Thermal Engineering 39 : 70-77. ScholarBank@NUS Repository. https://doi.org/10.1016/j.applthermaleng.2012.01.041
dc.identifier.issn13594311
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/85766
dc.description.abstractWe present the experimental investigation on the performance of multi-bed desiccant dehumidification system (MBDD) using a thermodynamic framework with an entropy generation analysis. The cyclic steady state performance of adsorption-desorption processes at the assorted heat source temperatures, and typical ambient humidity conditions was carried out. MBDD unit uses type-RD silica gel pore surface area with of 720 m 2/g. It has a nominal diameter range of 0.4 to 0. 7 mm. The key advantages of MBDD are: (i) it has no moving parts rendering less maintenance, (ii) energy-efficient means of dehumidification by adsorption process with low temperature heat source as compared to the conventional methods, (iii) although it is a pecked bed desiccant, a laminar chamber is employed by arranging the V-shaped configuration of heat exchangers and (iv) it is environmental friendly with the low-carbon footprint. Entropy generation analysis was performed at the assorted heat source temperatures to investigate the performance of MBDD. By conducting the entropy minimization, it is now able to locate the optimal operating conditions of the system while the specific entropy generation is found to be minimal. This analysis shows that the minimization of entropy generation in the dehumidification cycle leads to the maximization of COP in the MBDD and thus, higher delivery of useful effects at the same input resources. © 2011 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.applthermaleng.2012.01.041
dc.sourceScopus
dc.subjectDesiccant dehumidifier
dc.subjectEntropy generation minimization
dc.subjectSilica gel
dc.subjectWaste heat recovery
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.applthermaleng.2012.01.041
dc.description.sourcetitleApplied Thermal Engineering
dc.description.volume39
dc.description.page70-77
dc.description.codenATENF
dc.identifier.isiut000302670200010
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.