Please use this identifier to cite or link to this item: https://doi.org/10.1039/c3an00070b
DC FieldValue
dc.titleNanostructured α-Fe2O3 platform for the electrochemical sensing of folic acid
dc.contributor.authorMaiyalagan, T.
dc.contributor.authorSundaramurthy, J.
dc.contributor.authorKumar, P.S.
dc.contributor.authorKannan, P.
dc.contributor.authorOpallo, M.
dc.contributor.authorRamakrishna, S.
dc.date.accessioned2014-10-07T09:08:23Z
dc.date.available2014-10-07T09:08:23Z
dc.date.issued2013-03-21
dc.identifier.citationMaiyalagan, T., Sundaramurthy, J., Kumar, P.S., Kannan, P., Opallo, M., Ramakrishna, S. (2013-03-21). Nanostructured α-Fe2O3 platform for the electrochemical sensing of folic acid. Analyst 138 (6) : 1779-1786. ScholarBank@NUS Repository. https://doi.org/10.1039/c3an00070b
dc.identifier.issn00032654
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/85469
dc.description.abstractα-Fe2O3 nanofibers are synthesized by a simple and efficient electrospinning method and the selective determination of folic acid (FA) is demonstrated in the presence of an important physiological interferent, ascorbic acid (AA), using the α-Fe2O3 nanofiber modified glassy carbon (GC) electrode at physiological pH. Bare GC electrode fails to determine the concentration of FA in the presence of a higher concentration of AA due to the surface fouling caused by the oxidized products of AA and FA. However, modification with α-Fe2O3 nanofibers not only separates the voltammetric signals of AA and FA by 420 mV between AA and FA, but also enhances higher oxidation current. The amperometric current response is linearly dependent on FA concentration in the range of 60-60 000 nM, and the α-Fe2O3 nanofiber modified electrode displayed an excellent sensitivity for FA detection with an experimental detection limit of 60 nM (1.12 × 10-10 M (S/N = 3)). Furthermore, the α-Fe2O3 nanofiber modified electrode showed an admirable selectivity towards the determination of FA even in the presence of a 1000-fold excess of AA and other common interferents. This modified electrode has been successfully applied for determination of FA in human blood serum samples. This journal is © The Royal Society of Chemistry.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1039/c3an00070b
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1039/c3an00070b
dc.description.sourcetitleAnalyst
dc.description.volume138
dc.description.issue6
dc.description.page1779-1786
dc.description.codenANALA
dc.identifier.isiut000314972500026
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.