Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.ijheatmasstransfer.2012.11.020
DC FieldValue
dc.titleA comparative study of flow boiling heat transfer and pressure drop characteristics in microgap and microchannel heat sink and an evaluation of microgap heat sink for hotspot mitigation
dc.contributor.authorAlam, T.
dc.contributor.authorLee, P.S.
dc.contributor.authorYap, C.R.
dc.contributor.authorJin, L.
dc.date.accessioned2014-10-07T09:00:07Z
dc.date.available2014-10-07T09:00:07Z
dc.date.issued2013
dc.identifier.citationAlam, T., Lee, P.S., Yap, C.R., Jin, L. (2013). A comparative study of flow boiling heat transfer and pressure drop characteristics in microgap and microchannel heat sink and an evaluation of microgap heat sink for hotspot mitigation. International Journal of Heat and Mass Transfer 58 (1-2) : 335-347. ScholarBank@NUS Repository. https://doi.org/10.1016/j.ijheatmasstransfer.2012.11.020
dc.identifier.issn00179310
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/84771
dc.description.abstractTwo phase microgap heat sink has a large potential to minimize the drawbacks associated with two phase microchannel heat sink, especially flow instabilities, flow reversal and lateral variation of flow and wall temperature between channels. This new concept of the two-phase microgap heat sink is very promising due to its high heat transfer rate and ease of fabrication. However, comparison of the performance of microgap heat sink (heat transfer, pressure drop and instability characteristics) with some conventional heat sink has not been investigated extensively. In this study, experiments have been conducted to investigate the heat transfer and pressure drop characteristics of deionized water (DI) in microgap heat sink and compare these experimental results with similar data obtained for microchannel heat sink. These studies are carried out with the inlet DI water temperatures 86 °C at different mass fluxes ranging from 400 to 1000 kg/m2 s, for effective heat flux 0-85 W/cm 2. High speed flow visualizations are conducted simultaneously along with experiments to illustrate the bubble characteristics in the microchannel and microgap heat sink. Experimental result shows that microgap heat sink performs better at high heat flux and low mass flux due to confined slug and annular boiling dominance and consequent delay of dryout phase. So, this microgap technology is promising and an effective method to dissipate very high heat fluxes in compact space with a smaller rate of coolant flow. Moreover, pressure drop is higher in microchannel than microgap heat sink at all the heat fluxes. In addition, encouraging results have been obtained using microgap as it can potentially mitigate local hotspot, reduce flow instabilities, flow reversal and maintain uniform wall temperatures over the heated surface. © 2012 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.ijheatmasstransfer.2012.11.020
dc.sourceScopus
dc.subjectFlow visualization
dc.subjectLocal hotspot
dc.subjectMicrochannel heat sink
dc.subjectMicrogap heat sink
dc.subjectPressure instability
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.ijheatmasstransfer.2012.11.020
dc.description.sourcetitleInternational Journal of Heat and Mass Transfer
dc.description.volume58
dc.description.issue1-2
dc.description.page335-347
dc.description.codenIJHMA
dc.identifier.isiut000315001800034