Please use this identifier to cite or link to this item: https://doi.org/10.1088/0953-8984/14/8/301
DC FieldValue
dc.titleThermal decomposition kinetics of amorphous carbon nitride and carbon films
dc.contributor.authorZhang, L.H.
dc.contributor.authorGong, H.
dc.contributor.authorWang, J.P.
dc.date.accessioned2014-10-07T04:38:20Z
dc.date.available2014-10-07T04:38:20Z
dc.date.issued2002-03-04
dc.identifier.citationZhang, L.H., Gong, H., Wang, J.P. (2002-03-04). Thermal decomposition kinetics of amorphous carbon nitride and carbon films. Journal of Physics Condensed Matter 14 (8) : 1697-1708. ScholarBank@NUS Repository. https://doi.org/10.1088/0953-8984/14/8/301
dc.identifier.issn09538984
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/83189
dc.description.abstractKinetic thermal degradation of amorphous carbon and carbon nitride films is studied. Significantly improved thermal stability was observed for films intensified with C-N, C=N, and C≡N bonds. When the N2% (percentage of nitrogen) in Ar/N2 during film deposition was varied from 0 to 30 at pressures of 3 × 10-3 and 16 × 10-3 Torr, the onset decomposition temperatures increased from 396 to 538 and from 340 to 360 °C, while the apparent activation energy ΔE at 60% residual weight increased from 149 to 158 and from 96 to 120 kJ mol-1, respectively. A change in the thermal stability was observed when the N2% reached 50. The films of higher bonding ratio and structural integration showed a single-step decomposition mechanism. They had ΔE values decreasing with the decomposition process, following convex-trend isothermal weight-loss curves. Films deposited using low-energy carbon plasma had higher contents of loosely bonded molecules; this resulted in a seemingly two-step decomposition and ΔE increasing with weight loss over a certain range. They followed concave-trend isothermal weight-loss curves. The overall decomposition mechanism could best be expressed in terms of nth-order reactions with the value of n closely related to film structures and reaction temperatures. Lower n-values are related to densely packed structure and higher temperature due to the increased diffusion barrier of the products.
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentMATERIALS SCIENCE
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1088/0953-8984/14/8/301
dc.description.sourcetitleJournal of Physics Condensed Matter
dc.description.volume14
dc.description.issue8
dc.description.page1697-1708
dc.description.codenJCOME
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.