Please use this identifier to cite or link to this item: https://doi.org/10.1109/TMAG.2012.2201457
DC FieldValue
dc.titleFirst-order reversal curve investigations on the effects of ion implantation in magnetic media
dc.contributor.authorGaur, N.
dc.contributor.authorPiramanayagam, S.N.
dc.contributor.authorMaurer, S.L.
dc.contributor.authorSteen, S.E.
dc.contributor.authorYang, H.
dc.contributor.authorBhatia, C.S.
dc.date.accessioned2014-10-07T04:28:28Z
dc.date.available2014-10-07T04:28:28Z
dc.date.issued2012
dc.identifier.citationGaur, N., Piramanayagam, S.N., Maurer, S.L., Steen, S.E., Yang, H., Bhatia, C.S. (2012). First-order reversal curve investigations on the effects of ion implantation in magnetic media. IEEE Transactions on Magnetics 48 (11) : 2753-2756. ScholarBank@NUS Repository. https://doi.org/10.1109/TMAG.2012.2201457
dc.identifier.issn00189464
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/82363
dc.description.abstractIon implantation of different ion species of varying mass on magnetic recording media was investigated. Except for helium (4He +) and cobalt (59Co +) ions, all the other ions showed reduction in saturation magnetization (M s). In fact, M s was reduced to ∼0 emu/cc at a fluence of 2 × 10 16 and 5 × 10 16 ions/cm 2 for antimony (121Sb +) and argon (40Ar +) ions, respectively. First-order reversal curves (FORC) showed a reduction in the switching field and distribution as the fluence of the implanted species increased. In addition, the magnetostatic interactions which were present in the media were found to be overwhelmed by an increase in exchange interaction as fluence increased. It was noticed that the heavier the implanted ion, the lower was the lateral range and straggle. A negative correlation was also observed between the straggle of the implanted species and the increased exchange interaction. This observation is expected to play a very crucial role in high-density patterned media fabrication. © 1965-2012 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/TMAG.2012.2201457
dc.sourceScopus
dc.subjectFirst-order reversal curves (FORC)
dc.subjection implantation
dc.subjectlateral range
dc.subjectperpendicular magnetic recording
dc.typeArticle
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1109/TMAG.2012.2201457
dc.description.sourcetitleIEEE Transactions on Magnetics
dc.description.volume48
dc.description.issue11
dc.description.page2753-2756
dc.description.codenIEMGA
dc.identifier.isiut000310194400006
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.