Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/80314
DC FieldValue
dc.titleCathodoluminescence microscopy of semiconductor devices using a novel detector with high collection and backscattered electron rejection efficiency
dc.contributor.authorPhang, J.C.H.
dc.contributor.authorChan, D.S.H.
dc.contributor.authorChim, W.K.
dc.contributor.authorLiu, Y.Y.
dc.contributor.authorLiu, X.
dc.date.accessioned2014-10-07T02:56:10Z
dc.date.available2014-10-07T02:56:10Z
dc.date.issued1998
dc.identifier.citationPhang, J.C.H.,Chan, D.S.H.,Chim, W.K.,Liu, Y.Y.,Liu, X. (1998). Cathodoluminescence microscopy of semiconductor devices using a novel detector with high collection and backscattered electron rejection efficiency. Diffusion and Defect Data Pt.B: Solid State Phenomena 63-64 : 159-170. ScholarBank@NUS Repository.
dc.identifier.issn10120394
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/80314
dc.description.abstractAn optically optimized light collector suitable for both panchromatic and spectroscopic cathodoluminescence (CL) analysis in the scanning electron microscope (SEM) is described. The light collector is a semiellipsoidal mirror of high ellipticity which ensures high optical coupling with a light guide to a monochromator. A light collection efficiency of over 85% is achieved. A high backscattered electron efficiency of better than 90% is achieved by using a low atomic material for the light collector. The high collection efficiency of the system allows CL images to be obtained from a cold field emission SEM with low total beam current. Examples of CL images obtained for semiconductor devices are shown to illustrate the high collection efficiency and high backscattered electron rejection efficiency of the system. With the system, a new CL contrast mechanism was observed in a silicon device with a passivation layer of Si3N4/a-SiO2 The contrast was observed between the Si3N4/a-SiO2/metal and the Si3N4/a-SiO2/SiO2 (thermal)/Si regions. The system was also used to monitor the hot-electron-injection-induced 2.7eV luminescence centres and the interfacial stress dependence of the 2.7eV CL peak build-up in SiO2-Si structures.
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentELECTRICAL ENGINEERING
dc.description.sourcetitleDiffusion and Defect Data Pt.B: Solid State Phenomena
dc.description.volume63-64
dc.description.page159-170
dc.description.codenDDBPE
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.