Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.chroma.2005.06.010
DC FieldValue
dc.titleDynamic hollow fiber-supported headspace liquid-phase microextraction
dc.contributor.authorJiang, X.
dc.contributor.authorBasheer, C.
dc.contributor.authorZhang, J.
dc.contributor.authorHian, K.L.
dc.date.accessioned2014-06-23T05:54:58Z
dc.date.available2014-06-23T05:54:58Z
dc.date.issued2005-09-16
dc.identifier.citationJiang, X., Basheer, C., Zhang, J., Hian, K.L. (2005-09-16). Dynamic hollow fiber-supported headspace liquid-phase microextraction. Journal of Chromatography A 1087 (1-2) : 289-294. ScholarBank@NUS Repository. https://doi.org/10.1016/j.chroma.2005.06.010
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/77432
dc.description.abstractWith the increasing concern over deteriorating environmental quality, the analysis of organic pollutants in air, water, and soil has become critically important. The development of simple, efficient, and inexpensive analytical sample pretreatment is crucial for monitoring and evaluating the environment. In this work, a dynamic hollow-fiber supported headspace liquid-phase microextraction (DHF-HS-LPME) approach was developed. In dynamic LPME, the extracting solvent is held within a hollow fiber, affixed to a syringe needle and immersed in the sample solution, and is moved to-and-fro by using a programmable syringe pump. The movement facilitates mass transfer from the sample to the solvent. Here, a similar approach was adopted, except that extraction was from the headspace rather than by direct immersion. Analysis of the extract was carried out by gas chromatography-mass spectrometry. The effect of sampling temperature, water, salt, dwelling time were investigated. Results indicated that this novel headspace microextraction method gave good analyte-enrichment factors, linear range, limits of detection and repeatability, all of which were evaluated by extracting PAHs from soil samples. This technique represents an inexpensive, convenient, fast and simple sample preparation of this class of semi-volatile organic compounds. © 2005 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.chroma.2005.06.010
dc.sourceScopus
dc.subjectEnvironmental analysis
dc.subjectHeadspace liquid-phase microextraction
dc.subjectPolycyclic aromatic hydrocarbons
dc.subjectProgrammable syringe pump
dc.typeConference Paper
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/j.chroma.2005.06.010
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume1087
dc.description.issue1-2
dc.description.page289-294
dc.description.codenJCRAE
dc.identifier.isiut000231185600037
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.