Please use this identifier to cite or link to this item:
https://doi.org/10.1016/S0021-9673(97)00667-5
DC Field | Value | |
---|---|---|
dc.title | Conventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and microfabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin C | |
dc.contributor.author | Rodriguez, I. | |
dc.contributor.author | Zhang, Y. | |
dc.contributor.author | Lee, H.K. | |
dc.contributor.author | Li, S.F.Y. | |
dc.date.accessioned | 2014-06-23T05:54:48Z | |
dc.date.available | 2014-06-23T05:54:48Z | |
dc.date.issued | 1997-09-26 | |
dc.identifier.citation | Rodriguez, I., Zhang, Y., Lee, H.K., Li, S.F.Y. (1997-09-26). Conventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and microfabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin C. Journal of Chromatography A 781 (1-2) : 287-293. ScholarBank@NUS Repository. https://doi.org/10.1016/S0021-9673(97)00667-5 | |
dc.identifier.issn | 00219673 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/77419 | |
dc.description.abstract | Fast, efficient analysis of fluorescein isothiocyanate anti-human IgG was achieved in a short-capillary and in a microfabricated glass chip. The capillary was 6 cm long from injection end to detector with electric field strength of 0.268 kV/cm. Analyses were performed within 1 min. A glass microchip device was fabricated using standard photolithographic procedures and chemical wet etching. The channels were seated using a direct bonding technique. For an effective length of 2.8 cm with electric field strength of 0.526 kV/cm, electrophoretic analysis was achieved in less than 16 s. Conventional capillary electrophoresis gave highly reproducible results and good detection limits. Analysis time was 2.5 min for a capillary with 47 cm effective length and electric field strength of 0.383 kV/cm. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0021-9673(97)00667-5 | |
dc.source | Scopus | |
dc.subject | Immunoglobulins | |
dc.subject | Instrumentation | |
dc.subject | Proteins | |
dc.type | Conference Paper | |
dc.contributor.department | CHEMISTRY | |
dc.description.doi | 10.1016/S0021-9673(97)00667-5 | |
dc.description.sourcetitle | Journal of Chromatography A | |
dc.description.volume | 781 | |
dc.description.issue | 1-2 | |
dc.description.page | 287-293 | |
dc.description.coden | JCRAE | |
dc.identifier.isiut | A1997YC19800032 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.