Please use this identifier to cite or link to this item: https://doi.org/10.1016/S0021-9673(97)00667-5
DC FieldValue
dc.titleConventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and microfabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin C
dc.contributor.authorRodriguez, I.
dc.contributor.authorZhang, Y.
dc.contributor.authorLee, H.K.
dc.contributor.authorLi, S.F.Y.
dc.date.accessioned2014-06-23T05:54:48Z
dc.date.available2014-06-23T05:54:48Z
dc.date.issued1997-09-26
dc.identifier.citationRodriguez, I., Zhang, Y., Lee, H.K., Li, S.F.Y. (1997-09-26). Conventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and microfabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin C. Journal of Chromatography A 781 (1-2) : 287-293. ScholarBank@NUS Repository. https://doi.org/10.1016/S0021-9673(97)00667-5
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/77419
dc.description.abstractFast, efficient analysis of fluorescein isothiocyanate anti-human IgG was achieved in a short-capillary and in a microfabricated glass chip. The capillary was 6 cm long from injection end to detector with electric field strength of 0.268 kV/cm. Analyses were performed within 1 min. A glass microchip device was fabricated using standard photolithographic procedures and chemical wet etching. The channels were seated using a direct bonding technique. For an effective length of 2.8 cm with electric field strength of 0.526 kV/cm, electrophoretic analysis was achieved in less than 16 s. Conventional capillary electrophoresis gave highly reproducible results and good detection limits. Analysis time was 2.5 min for a capillary with 47 cm effective length and electric field strength of 0.383 kV/cm.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0021-9673(97)00667-5
dc.sourceScopus
dc.subjectImmunoglobulins
dc.subjectInstrumentation
dc.subjectProteins
dc.typeConference Paper
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/S0021-9673(97)00667-5
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume781
dc.description.issue1-2
dc.description.page287-293
dc.description.codenJCRAE
dc.identifier.isiutA1997YC19800032
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.