Please use this identifier to cite or link to this item: https://doi.org/10.1016/S0021-9673(01)01199-2
DC FieldValue
dc.titleDetermination of phenols in water using liquid phase microextraction with back extraction combined with high-performance liquid chromatography
dc.contributor.authorZhao, L.
dc.contributor.authorLee, H.K.
dc.date.accessioned2014-06-23T05:36:03Z
dc.date.available2014-06-23T05:36:03Z
dc.date.issued2001-10-05
dc.identifier.citationZhao, L., Lee, H.K. (2001-10-05). Determination of phenols in water using liquid phase microextraction with back extraction combined with high-performance liquid chromatography. Journal of Chromatography A 931 (1-2) : 95-105. ScholarBank@NUS Repository. https://doi.org/10.1016/S0021-9673(01)01199-2
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/75902
dc.description.abstractLiquid phase microextraction with back extraction (LPME/BE) combined with high-performance liquid chromatography (HPLC) was studied for the determination of a variety of phenols in water samples. The target compounds were extracted from 2-ml aqueous sample adjusted to pH 1 (donor solution) through a microliter-size organic solvent phase (400-μl n-hexane), confined inside a small PTFE ring, and finally into a 1-μl basic aqueous acceptor microdrop suspended in the aforementioned solvent phase from the tip of a microsyringe needle. After extracting for a prescribed time, the microdrop was taken back into the syringe and directly injected into an HPLC for detection. Factors relevant to the extraction procedure were studied. At the optimized extraction conditions, a large enrichment factor (more than 100-fold) can be achieved for most of the phenols within 35 min. The detection limit range was 0.5-2.5 μg/l for different analytes in aqueous samples. The results demonstrate the suitability of the LPME/BE approach to the analysis of polar compounds in aqueous samples. © 2001 Elsevier Science B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0021-9673(01)01199-2
dc.sourceScopus
dc.subjectExtraction methods
dc.subjectLiquid phase microextraction with back extraction
dc.subjectPhenols
dc.subjectWater analysis
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/S0021-9673(01)01199-2
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume931
dc.description.issue1-2
dc.description.page95-105
dc.description.codenJCRAE
dc.identifier.isiut000171541800007
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.