dc.titleDetermination of nitrate in seawater by capillary zone electrophoresis with chloride-induced sample self-stacking
dc.contributor.authorTu, C.
dc.contributor.authorLee, H.K.
dc.date.accessioned2014-06-23T05:36:00Z
dc.date.available2014-06-23T05:36:00Z
dc.date.issued2002-08-09
dc.identifier.citationTu, C., Lee, H.K. (2002-08-09). Determination of nitrate in seawater by capillary zone electrophoresis with chloride-induced sample self-stacking. Journal of Chromatography A 966 (1-2) : 205-212. ScholarBank@NUS Repository. https://doi.org/10.1016/S0021-9673(02)00744-6
dc.identifier.issn00219673
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/75897
dc.description.abstractA capillary zone electrophoresis (CZE) method was established to determine low concentration nitrate which was online preconcentrated with chloride-induced leading-type sample self-stacking for seawater samples. The sample self-stacking was based on transient isotachophoresis in which chloride served as leading ion, and dihydrogenphosphate in the background electrolyte (0.1 M phosphate) as the terminating one. Due to the small mobility difference between nitrate and chloride, the isotachophoresis time was so long that nitrate could not separate from the rear sharp boundary between chloride and the background electrolyte (BGE) when it migrated to the detection window. A zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)propane sulfonate was added to the BGE to enlarge the mobility difference for its selective interaction with anions. Thus, a highly conductive sample could be injected in a large volume with about fourfold sensitivity enhancement compared to that of field amplification sample stacking in which nitrate was dissolved in pure water. The relative standard deviations (n=5) of migration time, peak area, peak height were 0.1, 3.0, 1.5%, respectively. The limit of detection (S/N=3) for nitrate was 35 μg/l in seawater samples with relatively low concentration BGE (0.1 M sodium phosphate, pH 6.2). The overall procedure consisting of online preconcentration and separation was as simple as routine CZE except for a slightly longer sample injection time (3-4 min). © 2002 Elsevier Science B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0021-9673(02)00744-6
dc.sourceScopus
dc.subjectEnvironmental analysis
dc.subjectInorganic anions
dc.subjectNitrate
dc.subjectSample stacking
dc.subjectWater analysis
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.1016/S0021-9673(02)00744-6
dc.description.sourcetitleJournal of Chromatography A
dc.description.volume966
dc.description.issue1-2
dc.description.page205-212
dc.description.codenJCRAE
dc.identifier.isiut000177334200020