Please use this identifier to cite or link to this item: https://doi.org/10.1007/s11095-008-9651-y
DC FieldValue
dc.titleInvestigation of electrostatic behavior of a lactose carrier for dry powder inhalers
dc.contributor.authorChow, K.T.
dc.contributor.authorZhu, K.
dc.contributor.authorTan, R.B.H.
dc.contributor.authorHeng, P.W.S.
dc.date.accessioned2014-06-19T06:14:43Z
dc.date.available2014-06-19T06:14:43Z
dc.date.issued2008-12
dc.identifier.citationChow, K.T., Zhu, K., Tan, R.B.H., Heng, P.W.S. (2008-12). Investigation of electrostatic behavior of a lactose carrier for dry powder inhalers. Pharmaceutical Research 25 (12) : 2822-2834. ScholarBank@NUS Repository. https://doi.org/10.1007/s11095-008-9651-y
dc.identifier.issn07248741
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/74639
dc.description.abstractPurpose. This study aims to elucidate the electrostatic behavior of a model lactose carrier used in dry powder inhaler formulations by examining the effects of ambient relative humidity (RH), aerosolization air flow rate, repeated inhaler use, gelatin capsule and tapping on the specific charge (nC/g) of bulk and aerosolized lactose. Materials and Methods. Static and dynamic electrostatic charge measurements were performed using a Faraday cage connected to an electrometer. Experiments were conducted inside a walk-in environmental chamber at 25°C and RHs of 20% to 80%. Aerosolization was achieved using air flow rates of 30, 45, 60 and 75 L/min. Results. The initial charges of the bulk and capsulated lactose were a magnitude lower than the charges of tapped or aerosolized lactose. Dynamic charge increased linearly with aerosolization air flow rate and RH. Greater frictional forces at higher air flow rate induced higher electrostatic charges. Increased RH enhanced charge generation. Repeated inhaler use significantly influenced electrostatic charge due to repeated usage. Conclusions. This study demonstrated the significance of interacting influences by variables commonly encountered in the use DPI such as variation in patient's inspiratory flow rate, ambient RH and repeated inhaler use on the electrostatic behavior of a lactose DPI carrier. © 2008 Springer Science+Business Media, LLC.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1007/s11095-008-9651-y
dc.sourceScopus
dc.subjectAerosol
dc.subjectCharge
dc.subjectDry powder inhaler
dc.subjectElectrostatic
dc.subjectTriboelectrification
dc.typeConference Paper
dc.contributor.departmentPHARMACY
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.description.doi10.1007/s11095-008-9651-y
dc.description.sourcetitlePharmaceutical Research
dc.description.volume25
dc.description.issue12
dc.description.page2822-2834
dc.description.codenPHREE
dc.identifier.isiut000261343500015
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.