Please use this identifier to cite or link to this item: https://doi.org/10.1109/RAMECH.2010.5513209
DC FieldValue
dc.titleModel-based design analysis for programmable remote center of motion in minimally invasive surgery
dc.contributor.authorYang, L.
dc.contributor.authorChng, C.B.
dc.contributor.authorChui, C.K.
dc.contributor.authorLau, D.P.C.
dc.date.accessioned2014-06-19T05:37:21Z
dc.date.available2014-06-19T05:37:21Z
dc.date.issued2010
dc.identifier.citationYang, L.,Chng, C.B.,Chui, C.K.,Lau, D.P.C. (2010). Model-based design analysis for programmable remote center of motion in minimally invasive surgery. 2010 IEEE Conference on Robotics, Automation and Mechatronics, RAM 2010 : 84-89. ScholarBank@NUS Repository. <a href="https://doi.org/10.1109/RAMECH.2010.5513209" target="_blank">https://doi.org/10.1109/RAMECH.2010.5513209</a>
dc.identifier.isbn9781424465033
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/73623
dc.description.abstractRemote center of motion (RCM) is an important concept in the kinematics for robotic minimally invasive surgery (MIS). This work focuses on the kinematic modeling of mechanism design for programmable RCM in MIS. Programmable RCM uses multiple joints coordination to maintain the isocenter of surgical tool manipulation during MIS. In this work, the kinematic task requirement is studied using a multibody system analysis approach. A generalized model based on closed-loop kinematic chain was proposed. Next, an appropriate serial manipulator was conceptualized and kinematically modeled. Finally, simulation-based evaluations were performed on virtual models built with modeling software tools. The contribution of this work is the introduction of a model-based design analysis methodical approach. This will provide a framework for the implementation of a model-based control scheme in robotic minimally invasive surgery. In addition, this work could offer potential insights to better innovations for mechanical RCM system. ©2010 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/RAMECH.2010.5513209
dc.sourceScopus
dc.subjectDevice design methodology
dc.subjectMedical robotics
dc.subjectRemote center motion
dc.subjectSimulation based design
dc.typeConference Paper
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1109/RAMECH.2010.5513209
dc.description.sourcetitle2010 IEEE Conference on Robotics, Automation and Mechatronics, RAM 2010
dc.description.page84-89
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.