Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.jmmm.2012.02.073
DC FieldValue
dc.titleEffect of pulse magnetic field stimulation on calcium channel current
dc.contributor.authorFan, J.
dc.contributor.authorLee, Z.H.
dc.contributor.authorNg, W.C.
dc.contributor.authorKhoa, W.L.
dc.contributor.authorTeoh, S.H.
dc.contributor.authorSoong, T.H.
dc.contributor.authorQin, Y.R.
dc.contributor.authorZhang, Z.Y.
dc.contributor.authorLi, X.P.
dc.date.accessioned2014-06-19T05:34:38Z
dc.date.available2014-06-19T05:34:38Z
dc.date.issued2012-10
dc.identifier.citationFan, J., Lee, Z.H., Ng, W.C., Khoa, W.L., Teoh, S.H., Soong, T.H., Qin, Y.R., Zhang, Z.Y., Li, X.P. (2012-10). Effect of pulse magnetic field stimulation on calcium channel current. Journal of Magnetism and Magnetic Materials 324 (21) : 3491-3494. ScholarBank@NUS Repository. https://doi.org/10.1016/j.jmmm.2012.02.073
dc.identifier.issn03048853
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/73399
dc.description.abstractThis study aimed to investigate the effect of low frequency and high amplitude pulse magnetic field (PMF) on Calcium ion channel current of cells. Measurements were done on the Human Embryonic Kidney 293 cells (HEK 293), which have only Calcium ion channels functioning. The whole cell current was measured by patch clamp method, with the clamped voltage ramping from -90 mV to 50 mV across the cell membrane. A PMF was generated by a 400-turn coil connected to a pulse current generator. The frequency of the pulse was 7 Hz, the width of the pulse was 3 ms, and the amplitude of the pulse, or the flux density, was ranging from 6 to 25 mT. The results showed that the profile of the whole cell Calcium channel current could be modified by the PMF. With the PMF applied, the phase shifting occurred: the onset of the channel opening took place several mili-seconds earlier than that without the PWF and correspondingly, the whole cell current reached its maximum earlier, and the current returned back to zero earlier as well. When the PWF was stopped, these effects persisted for a period of time, and then the current profile recovered to its original appearance. The decrease of the onset time and peak current time could be due to the local electric potential induced by the PWF and the direct interaction between PMF and ion channels/ions. The exact mechanisms of the observed effects of PMF on the cell are still unknown and need to be further studied. © 2012 Elsevier B.V.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.jmmm.2012.02.073
dc.sourceScopus
dc.subjectIon channel
dc.subjectPatch clamp
dc.subjectPulse magnetic field
dc.typeConference Paper
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.jmmm.2012.02.073
dc.description.sourcetitleJournal of Magnetism and Magnetic Materials
dc.description.volume324
dc.description.issue21
dc.description.page3491-3494
dc.description.codenJMMMD
dc.identifier.isiut000306418500028
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.