Please use this identifier to cite or link to this item: https://doi.org/10.1063/1.3148295
DC FieldValue
dc.titleMagnetic nanoparticle migration in microfluidic two-phase flow
dc.contributor.authorWu, L.
dc.contributor.authorZhang, Y.
dc.contributor.authorPalaniapan, M.
dc.contributor.authorRoy, P.
dc.date.accessioned2014-06-19T03:17:05Z
dc.date.available2014-06-19T03:17:05Z
dc.date.issued2009
dc.identifier.citationWu, L., Zhang, Y., Palaniapan, M., Roy, P. (2009). Magnetic nanoparticle migration in microfluidic two-phase flow. Journal of Applied Physics 105 (12) : -. ScholarBank@NUS Repository. https://doi.org/10.1063/1.3148295
dc.identifier.issn00218979
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/70859
dc.description.abstractContinuous separation of superparamagnetic nanoparticles in a microfluidic system has numerous applications, especially in novel sensors based technology platforms. We have studied a simple microfluidic system with two fluidic inlets, resulting in two-phase flow of identical aqueous fluids. Magnetic nanoparticles were entrained in de-ionized water entering one inlet channel, while the other inlet channel had only de-ionized water input. The application of a magnetic field using a simple permanent magnet causes increased migration of nanoparticles into the pure fluid channel. In the absence of the magnetic field, the particles are able to diffuse into the particle free phase. A steady state convection diffusion model describes the transport of nanoparticles in the microchannel. Particle velocities are estimated from magnetic and hydrodynamic interaction forces. It is shown how particle separation is affected by Ṕclet number, channel length to width ratio, and magnetic field strength and field gradient. Experiments were conducted with three particle sizes, 1000, 500, and 100 nm. Results revealed a significant discrepancy between theoretical and experimental particle separations under the applied magnetic field. A correction term was introduced into the magnetic force equation. Experiment and theory could be reconciled with the insight that the correction term scales linearly with the volume of the nanoparticle core. © 2009 American Institute of Physics.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1063/1.3148295
dc.sourceScopus
dc.typeConference Paper
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.contributor.departmentBIOENGINEERING
dc.description.doi10.1063/1.3148295
dc.description.sourcetitleJournal of Applied Physics
dc.description.volume105
dc.description.issue12
dc.description.page-
dc.description.codenJAPIA
dc.identifier.isiut000267599600090
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.