Please use this identifier to cite or link to this item: https://doi.org/10.1109/APEC.2012.6165833
DC FieldValue
dc.titleA multimode digital control scheme for boost PFC with higher efficiency and power factor at light load
dc.contributor.authorLim, S.F.
dc.contributor.authorKhambadkone, A.M.
dc.date.accessioned2014-06-19T02:54:28Z
dc.date.available2014-06-19T02:54:28Z
dc.date.issued2012
dc.identifier.citationLim, S.F.,Khambadkone, A.M. (2012). A multimode digital control scheme for boost PFC with higher efficiency and power factor at light load. Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC : 291-298. ScholarBank@NUS Repository. <a href="https://doi.org/10.1109/APEC.2012.6165833" target="_blank">https://doi.org/10.1109/APEC.2012.6165833</a>
dc.identifier.isbn9781457712159
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/68895
dc.description.abstractConstant frequency controllers designed for continuous conduction mode (CCM) give poor efficiency and power factor at light load in power factor correctors (PFCs) of computer and server power supplies. With the increasing efficiency and power factor requirements at light load demanded by energy saving programs, a multimode digital control scheme that provides higher efficiency and power factor at light load without additional and costly external components is proposed. The CCM-DCM control of the multimode control scheme reduces RMS current drawn from the AC mains by ensuring good input current shaping in both CCM and discontinuous conduction mode (DCM), leading to higher efficiency and power factor at light load. It is computationally simple as compared to other CCM-DCM control schemes. The no load control of the multimode control scheme reduces constant losses at very light load by turning the PFC on and off to regulate the output voltage within a hysteresis band. Compared to other on-off control schemes, a small load jump is sufficient to exit the proposed no load control scheme, allowing a smooth transition between the no load control and the CCM-DCM active mode control. © 2012 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/APEC.2012.6165833
dc.sourceScopus
dc.typeConference Paper
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1109/APEC.2012.6165833
dc.description.sourcetitleConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
dc.description.page291-298
dc.description.codenCPAEE
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.