Please use this identifier to cite or link to this item: https://doi.org/10.1117/1.3374051
DC FieldValue
dc.titleRapid near-infrared fluorescence excitation-emission matrix spectroscopy for multifluorophore characterization using an acousto-optic tunable filter technique
dc.contributor.authorLi, H.
dc.contributor.authorZheng, W.
dc.contributor.authorHuang, Z.
dc.date.accessioned2014-06-17T09:46:16Z
dc.date.available2014-06-17T09:46:16Z
dc.date.issued2010
dc.identifier.citationLi, H., Zheng, W., Huang, Z. (2010). Rapid near-infrared fluorescence excitation-emission matrix spectroscopy for multifluorophore characterization using an acousto-optic tunable filter technique. Journal of Biomedical Optics 15 (2) : -. ScholarBank@NUS Repository. https://doi.org/10.1117/1.3374051
dc.identifier.issn10833668
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/67251
dc.description.abstractWe report on a novel acousto-optic tunable filter (AOTF)-based near-infrared (NIR) fluorescence excitation-emission matrix (EEM) spectroscopy technique for rapid multifluorophore characterization. We implement a unique light filtering module design by using cascaded AOTFs coupled with three orthogonally oriented polarizers to effectively remove the side-ripple artifacts of AOTFs as well as by using a pair of AOTFs coupled with two orthogonally oriented polarizers to improve detection efficiency for high-quality fluorescence EEM acquisitions. NIR fluorescence EEM spectroscopy (41 excitation wavelengths ranging from 550 to 950 nm in 10-nm increments; fluorescence emission from 570 to 1000 nm at 10-nm intervals) can be acquired from fluorescence dyes [e.g., diethylthiatricarbocyanine (DTTC) iodide, oxazine 750, and IR 140] within 10 s or even less, illustrating the potential of the AOTF-based NIR EEM technique developed for rapid multifluorophore analysis and characterization in biochemical and biomedical systems. © 2010 Society of Photo-Optical Instrumentation Engineers.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1117/1.3374051
dc.sourceScopus
dc.subjectAcousto-optic tunable filter (AOTF)
dc.subjectExcitation-emission matrices (EEMS)
dc.subjectFluorescence
dc.subjectNear-infrared (NIR) fluorescence
dc.subjectSpectroscopy
dc.typeArticle
dc.contributor.departmentBIOENGINEERING
dc.description.doi10.1117/1.3374051
dc.description.sourcetitleJournal of Biomedical Optics
dc.description.volume15
dc.description.issue2
dc.description.page-
dc.description.codenJBOPF
dc.identifier.isiut000278465300070
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.