Please use this identifier to cite or link to this item:
https://doi.org/10.1117/1.3374051
DC Field | Value | |
---|---|---|
dc.title | Rapid near-infrared fluorescence excitation-emission matrix spectroscopy for multifluorophore characterization using an acousto-optic tunable filter technique | |
dc.contributor.author | Li, H. | |
dc.contributor.author | Zheng, W. | |
dc.contributor.author | Huang, Z. | |
dc.date.accessioned | 2014-06-17T09:46:16Z | |
dc.date.available | 2014-06-17T09:46:16Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | Li, H., Zheng, W., Huang, Z. (2010). Rapid near-infrared fluorescence excitation-emission matrix spectroscopy for multifluorophore characterization using an acousto-optic tunable filter technique. Journal of Biomedical Optics 15 (2) : -. ScholarBank@NUS Repository. https://doi.org/10.1117/1.3374051 | |
dc.identifier.issn | 10833668 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/67251 | |
dc.description.abstract | We report on a novel acousto-optic tunable filter (AOTF)-based near-infrared (NIR) fluorescence excitation-emission matrix (EEM) spectroscopy technique for rapid multifluorophore characterization. We implement a unique light filtering module design by using cascaded AOTFs coupled with three orthogonally oriented polarizers to effectively remove the side-ripple artifacts of AOTFs as well as by using a pair of AOTFs coupled with two orthogonally oriented polarizers to improve detection efficiency for high-quality fluorescence EEM acquisitions. NIR fluorescence EEM spectroscopy (41 excitation wavelengths ranging from 550 to 950 nm in 10-nm increments; fluorescence emission from 570 to 1000 nm at 10-nm intervals) can be acquired from fluorescence dyes [e.g., diethylthiatricarbocyanine (DTTC) iodide, oxazine 750, and IR 140] within 10 s or even less, illustrating the potential of the AOTF-based NIR EEM technique developed for rapid multifluorophore analysis and characterization in biochemical and biomedical systems. © 2010 Society of Photo-Optical Instrumentation Engineers. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1117/1.3374051 | |
dc.source | Scopus | |
dc.subject | Acousto-optic tunable filter (AOTF) | |
dc.subject | Excitation-emission matrices (EEMS) | |
dc.subject | Fluorescence | |
dc.subject | Near-infrared (NIR) fluorescence | |
dc.subject | Spectroscopy | |
dc.type | Article | |
dc.contributor.department | BIOENGINEERING | |
dc.description.doi | 10.1117/1.3374051 | |
dc.description.sourcetitle | Journal of Biomedical Optics | |
dc.description.volume | 15 | |
dc.description.issue | 2 | |
dc.description.page | - | |
dc.description.coden | JBOPF | |
dc.identifier.isiut | 000278465300070 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.