Please use this identifier to cite or link to this item: https://doi.org/10.1177/1475921704042679
DC FieldValue
dc.titleFiber optic sensing for monitoring corrosion-induced damage
dc.contributor.authorMaalej, M.
dc.contributor.authorAhmed, S.F.U.
dc.contributor.authorKuang, K.S.C.
dc.contributor.authorParamasivam, P.
dc.date.accessioned2014-06-17T08:18:30Z
dc.date.available2014-06-17T08:18:30Z
dc.date.issued2004
dc.identifier.citationMaalej, M., Ahmed, S.F.U., Kuang, K.S.C., Paramasivam, P. (2004). Fiber optic sensing for monitoring corrosion-induced damage. Structural Health Monitoring 3 (2) : 165-176. ScholarBank@NUS Repository. https://doi.org/10.1177/1475921704042679
dc.identifier.issn14759217
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/65593
dc.description.abstractThis paper reports the feasibility of using embedded Fabry-Perot fiber optic sensors to detect and monitor the propagation of cracks and delamination within concrete beams induced by corrosion of the reinforcing bars. In this research, four series of reinforced concrete beams were subjected to varying degrees of corrosion-induced damage by modifying the composition of the concrete mix and subjecting all specimens to the same accelerated corrosion environment. The concept employed in this study involves embedding the Fabry-Perot sensor between two reinforcing bars to measure the transverse tensile strains associated with the longitudinal crack along the reinforcing bars (and in severe cases, delamination of the concrete beam) resulting from the radial expansion of the corroding rebars. Excellent correlation was obtained between the Fabry-Perot strain data and the amount of steel loss resulting from accelerated corrosion. In addition, the optical sensor strain readings and the reductions in the load-carrying and deflection capacities were also observed to exhibit strong positive correlation highlighting the potential of the optical sensor to monitor the progression of the rebar damage and the loss of structural integrity of the beams resulting from the extensive corrosion. The technique used in this study demonstrates the possibility of detecting corrosion-induced damage in reinforced concrete structures, particularly those where visual inspection is not possible. Copyright © 2004 Sage Publications.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1177/1475921704042679
dc.sourceScopus
dc.subjectCorrosion damage
dc.subjectDelamination
dc.subjectFiber optic strain sensor
dc.subjectSpalling
dc.subjectStructural health monitoring
dc.typeArticle
dc.contributor.departmentCIVIL ENGINEERING
dc.description.doi10.1177/1475921704042679
dc.description.sourcetitleStructural Health Monitoring
dc.description.volume3
dc.description.issue2
dc.description.page165-176
dc.identifier.isiut000224289400004
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.